HP MSA70
|
|
Bookmark HP MSA70 |
HP StorageWorks Modular Smart Array 70 Storage enclosure - 25-bayRack-mountable - 2U, 0 hot-swap, PC, Unix
The HP StorageWorks 70 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 2.5" SAS or Serial ATA (SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 2.5" Universal SAS or SATA hard drive form factors. [ Report abuse or wrong photo | Share your HP MSA70 photo ]
Manual
Download
(English)HP MSA70 - Installation, size: 245 KB |
HP MSA70
User reviews and opinions
| henk99 |
11:35pm on Sunday, March 28th, 2010 ![]() |
| Disco Duro compatible con servidor HP DL 360 Este disco es compatible perfectamente con un servidor HP DL 360. Disco Duro compatible con servidor HP DL 360 Este disco es compatible perfectamente con un servidor HP DL 360. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents
QuickSpecs
Overview
HP StorageWorks 70 Modular Smart Array
The HP StorageWorks 70 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 2.5 inch SAS or Serial ATA (SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 2.5 inch Universal SAS and SATA hard drive form factors. The MSA70 enclosure supports direct attach storage (DAS) to HP ProLiant and Integrity Servers. The MSA70 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 50 drives in a 4U configuration behind each of the two external ports on the HP Smart Array P800, the HP Smart Array E500, the HP Smart Array P411, the HP Smart Array P212 or the P812 Controller for a total of 100 drives in 4 enclosures (a single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS). (NOTE: Smart Array P411 and P812 Controllers are supported on NOTE: ProLiant servers only). On HP ProLiant servers Dual Domain support is available for the HP Smart Array P800 attached to a MSA70 with the addition of the HP StorageWorks Dual Domain I/O Module Option (AG779A). (Single initiator environment only.) The MSA70 also supports the HP Smart Array P600 and the HP Smart Array P212 Controllers. Behind the single external port on the HP Smart Array P600 controller 1+1 cascading allows a maximum of 50 drives in a 4U configuration. (NOTE: Smart Array P212 NOTE: Controller is supported on ProLiant servers only). For HP-UX and Open VMS environments on selected HP Integrity Servers the MSA70 supports the HP (AH303A) SC44Ge Host Bus Adapter with the addition of the HP StorageWorks Dual Domain I/O Module Option (AG779A). Behind the single external port on the HP (AH303A) SC44Ge Host Bus Adapter 1+1 cascading allows a maximum of 50 drives in a 4U configuration. The HP (AH303A) SC44Ge Host Bust Adapter will only support HP-UX and Open VMS environments and will be available on all rack mounted HP Integrity Servers with PCIe slots. The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will support HP-UX and Open VMS on selected HP Integrity servers only. The MSA70 with the I/O Module and the HP SC44Ge Host Bus Adaptor will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only. Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only. HP Serviceguard monitors the health of each node and rapidly responds to failures in a way that minimizes or eliminates application downtime. NOTE: HP Integrity servers that are supported: rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards) The MSA70 is also supported when attached to a HP StorageWorks MSA2000 G2 or P2000 G3 Small Form Factor (SFF) Arrays. The SFF MSA2000 G2 or the P2000 G3 can accommodate up to twenty four (24) SFF drives and is designed for small to medium size department and remote locations. The MSA2000 G2 supports attachment of up to three (3) dual I/O MSA70 SFF JBODs (99 SFF drives). P2000 G3 Arrays support attachment of up to five(5) dual I/O MSA70 SFF JBODs (149 SFF drives).
What's New
Adding support for tthree new SAS drives HP 900 GB 6G SAS 10K SFF (2.5inch) DP ENT HDD HP 1TB 6G SAS 7.2K SFF (2.5inch) DP MDL HDD HP 1TB 3G SATA 7.2K SFF (2.5inch) MDL HDD
DA - 12652
Worldwide Version 35 May 27, 2011
Page 1
Front panel LEDs and buttons 1. Status LED 2. Fault LED 3. UID button/LED
Rear Panel components 1. Power supply 1 2. Fan module 1 3. 7- segment display board 4. SAS in connector 5. SAS out connector
6. 7. 8. 9.
I/O module bay I/O module bay Fan module 2 Power supply 2
Page 2
At A Glance
3G SAS host connectivity Dual Domain support with HP Smart Array P800 Controller for HP ProLiant and Integrity servers (requires dual port SAS drives) (single environment only) Multi Initiator support with the SC44Ge Host Bus Adapter (AH303A) (HP-UX and Open VMS on selected HP Integrity Servers) with dual port SAS drives only Supports twenty five 2.5 inch hot pluggable drives Supports HP 6G SAS Dual-port disk drives, (146 GB, 300 GB, 600 GB & 900 GB capacities) Supports HP 6G SAS Dual-port Midline (MDL) disk drives (500 GB & 1 TB capacities) Supports HP SATA 3G disk drives, (500 GB & 1 TB capacities) Maximum storage capacity of 22.5 TB (with twenty five 900 GB 6G DP SAS), 25 TB (with twenty five 1 TB 6G SAS DP MDL) or 25 TB (with twenty five HP SATA 3G 1 TB hard drives) Attached to HP SC44Ge Host Bus Adapter for HP-UX and Open VMs support on selected HP Integrity Servers (servers that support PCI-e cards) Supports attachment of up to three (3) dual I/O MSA70 behind a Small Form Factor MSA2000 G2 (99 SFF drives for a total of 59.4TB SAS or 24.7TB SATA) (NOTE: MSA70 is NOT supported behind a MSA2000 G2 (LFF)).Supports MS Windows 2003, Microsoft Windows 2008, Red Hat Linux, SUSE Linux, VMware, Novell NetWare, HP-UX 11iv2 and 11iv3, Open VMS 8.3 1H Supports attachment of up to five (5) dual I/O MSA70 behind a Small Form Factor P2000 G3 (149 SFF drives for a total of 89.4TB SAS or 74.5TB SAS MDL or SATA ) (NOTE: MSA70 is NOT supported behind a P2000 G3 (LFF)) 1+1 Cascade support (behind a single SAS port) Supports boot from storage Redundant hot-plug power supplies and fans standard Addition of second I/O Module adds Dual Domain capability providing higher level of redundancy and reliability
Page 3
Standard Features
Modular Smart Array Family
The HP StorageWorks Modular Smart Array family delivers simple, affordable storage technology to meet today's demanding and growing IT needs. These storage solutions offer the best price/performance and best price/availability features for direct attach environments, small clusters, workgroups and entrylevel SAN environments. Each solution is designed to be easy to deploy, secure, and reduce management costs, while driving rapid return on investment.
Modular Smart Array 70
The HP StorageWorks 70 Modular Smart Array is an end-to-end flexible storage array, offering data availability, enhanced reliability, enhanced performance and tiered storage capability with SAS and SATA drives and investment protection. Manage your small and midrange business growing storage needs by deploying this low cost, flexible tiered storage system with up to 90 TB SAS, 100 TB SAS MDL or SATA MDL (100 drives across four enclosures) capacity supporting both SAS and SATA. The modular, scalable design of the MSA70 provides a flexible platform allowing you to buy what is needed today and purchase additional capacity as data storage needs grow, instead of making a large up-front investment. Additional drives and enclosures can be easily added as customer needs dictate without extra management charges as needs grow. For Small businesses, it is a stepping stone to simplify capacity expansion of HP ProLiant and HP Integrity Server environments to external storage without having to make the full move to SAN or NAS. For fast growing Small or Medium businesses MSA70 can scale to multiple TBytes, by adding additional drive bays. This enclosure is designed to support the 2.5 inch Universal form factor hard drive in either SAS or SATA. Configuration and setup is easy with HP Array Configuration Utility (ACU). The 2U storage supports direct attach storage to HP ProLiant and HP Integrity Servers. Enclosures can be cascaded in a 1+1 configuration allowing a maximum of 50 drives in a 4U configuration behind each port on the Smart Array P800, E500, P411 or the P812 controller for a total of 100 drives. The MSA70 is also supported when attached to a HP StorageWorks MSA2000 G2 or P2000 G3 Small Form Factor (SFF) Arrays. The SFF MSA2000 G2 or the P2000 G3 can accomodate up to twenty four (24) SFF drives and is designed for small to medium size department and remote locations. The MSA2000 G2 supports attachment of up to three (3) dual I/O MSA70 SFF JBODs (99 SFF drives). P2000 G3 Arrays support attachment of up to five(5) dual I/O MSA70 SFF JBODs (149 SFF drives).
Page 4
Key Features Affordability
MSA70 provides end-to-end SAS host modular flexible platform in a high capacity 2U disk drive external direct storage system 2U SFF SAS/SATA allows customer choice. Extends the benefit of tiered Flexibility storage to direct attach customers Modular platform allows customers to purchase based on current need and Investment protection future growth, no hidden management charges. Simplicity: Manageability Manage the array with the highly refined HP Systems Insight Manager Up to 2 enclosures can be connected together to form a single controller Cascadeability port. Grow storage capacity easily Hot plug compatibility: can add or replace hard drives without service Reliability disruption RAID levels provide various levels of data protection and availability. RAID level choices provide flexibility. RAID 6 with ADG provides additional level reliability Serviceguard maximizes application availability while protecting data High Availability integrity. (HP-UX and Open VMS support on selected HP Integrity Servers only) HP Portfolio - end-to-end HP offers a complete portfolio of SAS storage enclosure, Smart Array Controllers and HP ProLiant and HP Integrity Servers for end-to-end solution solution leading the competition
Page 5
Product Highlights
High Levels of Storage Density, Data Protection, and Functionality
Storage Capacity - The MSA70 enclosure supports up to twenty five 2.5 inch SAS or SATA drives for a maximum capacity of 22.5 TB with 900GB SAS drives, 25 TB SAS MDL or SATA MDL drives. Data Protection - MSA70 is designed for a high level of data protection. It includes redundant fans and power supplies (standard), and support for various RAID levels including RAID 6 with ADG (depending upon the Smart Array Controller used). Dual Domain - Dual domain SAS creates redundant pathways from servers to storage devices. The redundant paths created by these configurations reduce or eliminate single points of failure within the storage network. This provides increased levels of high availability with redundant paths from the controller to the drives. Storage Manageability - The MSA70 features familiar configuration and management tools such as Array Configuration Utility (ACU) and HP Systems Insight Manager (SIM). Online Management Features include: Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size Migration, Online Spares. Choice of Computing Platform - The MSA70 is designed and qualified for HP ProLiant and HP Integrity servers. Advanced Data Guarding (RAID 6 with ADG) Fault Tolerance - It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.
Low Total Cost of Ownership
The modular, scalable design of the MSA70 provides an extremely flexible platform. You can buy what you need today and purchase additional capacity as your data storage needs grow, instead of making a large up-front investment. Additional drives and enclosures can be easily added as your needs dictate. Cascading - The MSA70 has the capability of cascading up to two (2) enclosures behind a single SAS port (depends on the Smart Array Controller). Tiered Storage - MSA70 supports mixing SAS and SATA drives in the same enclosure, allowing you to more effectively utilize mission critical storage where you need it most. SupportUniversal SATA Hard Drive Support Since the MSA70 supports HP Universal SATA drives, your investment in disk drives is protected and cost is minimized as you add new drives. Pre-Failure Warranty - Drives installed in a MSA70 and monitored under HP Systems Insight Manager are supported by a Pre-Failure (replacement) Warranty (3 years for SAS and 1 year for SAS MDL or SATA drives). Pre-Failure Warranty allows for the replacement of designated drives in MSA70 before they actually fail when using HP Systems Insight Manager on HP ProLiant or HP Integrity servers. NOTE: Some operating systems may not support all of these features. Integrated Configuration and Management Tools - The MSA70 utilizes the standard, integrated set of Smart Array management and utility software for HP ProLiant Servers. These tools consistently lower the cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage. HP-UX and Open VMS uses HP Integrity ODE for storage enclosure support.
Page 6
Modular Smart Array 70 Components
MSA70 Enclosure
The 2U array houses up to twenty five 2.5 inch Universal hot pluggable SAS or SATA hard drives. Each MSA70 includes the following standard components: MSA70 base enclosure with redundant power supplies and fan modules Rack mounting hardware kit 0.5m mini-SAS cable Two AC power cords & two PDU interconnect cords
Smart Array P800 Features
HP's highest performing 16-port PCI-express controller with expander support Expander support enables the addition of external storage, allowing increased number of drives for increased performance Provides highest level of data protection standard by using RAID 6 with Advanced Data Guarding Supports a maximum of 108 drives (100 drives across four enclosures plus 8 drives in the server internal backplane) Supported in a single initiator environment For more information see: http://h18004.www1.hp.com/products/quickspecs/12616_div/12616_div.html
Smart Array E500 Features
HP's first external connect only PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller Expander support enables the addition of external storage, allowing increased number of drives for increased performance Offers RAID 0, 1 & 1+0 and can be upgraded with battery-backed write cache (BBWC) module for RAID 5 Supports a maximum total of 108 hard drives Supported in a single initiator environment For more information see: http://h18004.www1.hp.com/products/quickspecs/12700_div/12700_div.html
Smart Array P411 Features
The HP Smart Array P411 is HP's PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller Low profile, half height card has 8 ports and utilizes DDR2-800 memory The P411 is ideal for RAID 0/1, 5, 1+0 & 5+0 and can be upgraded with the 512MB batterybacked write cache (BBWC) module and Smart Array Advanced via license key for RAID 6 &, 6 + 0,50 & 60 For more information see: http://h18004.www1.hp.com/products/quickspecs/13202_div/13202_div.html
Smart Array P212 Features
The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller The Low Profile, Half Height card has 8 ports and utilizes DDR2-266 memory The P212 is ideal for RAID 0/1, 1+0 and can be upgraded with the 256MB battery-backed write cache (BBWC) module for RAID 5, 5+0 For more information see: http://h18004.www1.hp.com/products/quickspecs/13203_div/13203_div.html
Page 7
Smart Array P812 Features
The HP Smart Array P812 provides superior RAID performance, while delivering high levels of connectivity, reliability, and many advanced features Increased connectivity with 8 internal ports and 16 external ports. 1 G 72-bit wide DDR2-800 flash-backed write cache (FBWC). Smart Array Advanced Pack (SAAP) license key included standard For moreinformation see: http://h18004.www1.hp.com/products/quickspecs/13558_div/13558_div.html
HP (AH303A) SC44Ge Host Bus Adapter
SAS technology delivers high performance and data bandwidth up to 3Gbp/s per physical link. PCI Express x8 capable PCIe x8 (2.5 GB/s bandwidth) Supported in a Multi Initiator environment
Several fault tolerant configurations keep data available and servers running while drives are being replaced - RAID levels that offer fault tolerance include: RAID 50 (RAID 5+0) protects against failure of one drive (and failure of particular multiple drives). RAID 50 is a nested RAID method that uses RAID 0 striping across RAID 5 arrays. RAID 50 tolerates one drive failure in each spanned array without loss of data. RAID 50 requires less rebuild time than single RAID 5 arrays RAID 50 requires a minimum of six drives. RAID 60 (RAID 6+0) allows administrators to split the RAID 6 storage across multiple external boxes. RAID 60 requires a minimum of eight drives. RAID 60 is a nested RAID method that uses RAID 0 block-level striping across multiple RAID 6 arrays with dual distributed parity. With the inclusion of dual parity, RAID 60 will tolerate the failure of two disks in each spanned array without loss of data. ADG: RAID 6 with ADG Allocates the equivalence of two parity drives across multiple drives and allows simultaneous write operations. Distributed Data Guarding (RAID 5): Allocates parity data across multiple drives and allows simultaneous write operations. Drive Mirroring (RAID 1 and 1+0 Striped Mirroring): Allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file.
Page 9
rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCIe cards) MSA2000 G2 Arrays NOTE: For information on supported Operating Systems please see the MSA2000 G2 Quickspecs: www.hp.com/go/msa2000 P2000 G3 Arrays NOTE: For information on supported Operating Systems please see the P2000 G3 Quickspecs: www.hp.com/go/P2000 NOTE: HPUX 11iv2/11.iv3 (for Dual Domain only) Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus Adapter or HP Smart Array P800 Controller (single initiator environment only) Qualified for the following HP Integrity servers: rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards) NOTE: Open VMS (for Dual Domain only) Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus Adapter Qualified for the following HP Integrity servers: rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)
Page 10
Service and Support
Service and Support, HP Care Pack, and Warranty Information
Three-year limited parts only warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services. NOTE: The MSA70 has a limited 3 year parts only warranty. SAS drives have 3 year warranty. SAS MDL and SATA drives have a 1 year warranty. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including: Installation and start up Education courses Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials solutions helping to deliver high level of application availability. Response times range from 30 minutes for critical problems to 2 hours. System Management, Performance Services and Mission Critical Support Solution Service includes HP branded hardware options qualified for the storage enclosure, purchased at the same time or afterwards, internal to the enclosure. These will be covered at the same service level and coverage period as the storage enclosure. NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack Information Flexible Support
1 Year Support
3 Year Support
HA101A1-87G HA103A1-87G HA104A1-87G HA105A1-87G HA109A1-87G HA110A1-87G HA111A1-87G HA112A1-87G HA101A3-87G HA103A3-87G HA104A3-87G
Page 11
HA105A3-87G HA109A3-87G HA110A3-87G HA111A3-87G HA112A3-87G HA101A4-87G HA103A4-87G HA105A4-87G HA109A4-87G HA110A4-87G HA111A4-87G HA112A4-87G HA101A5-87G HA103A5-87G HA105A5-87G HA109A5-87G HA110A5-87G HA111A5-87G HA112A5-87G HA113A1-564 UF297E UF298E UF299E UF300E UF301E UF302E UF303E UF304E UF305PE UF306PE UF307PE UF308PE U8132E
4 Year Support
5 Year Support
Fixed Care Packs
Installation & Support HP 1y NBD 9x5 MSA70 HW Support HP 1y 4h 13x5 MSA70 HW Support HP 1y 4h 24x7 MSA70 HW Support HP 1y 6h ctr MSA70 HW Support HP 3y NBD 9x5 MSA70 HW Support HP 3y 4h 13x5 MSA60 HW Support HP 3y 4h 24X7 MSA70 HW Support HP 3y 6h CTR MSA70 HW Support HP 1y PW NBD MSA70 HW Support HP 1y PW 4h 13X5 MSA70 HW Support HP 1y PW 4h 24X7 HP 1y PW NBD MSA70 HW Support Hardware Installation, Electronic
Page 12
Configuration Information
Step 1: Order Required Items
Model MSA70 I/O Module Shipping Dimensions HP Storage Works 70 Modular Smart Array HP StorageWorks Dual Domain I/O Module NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA70 will allow dual domain capability providing higher level of redundancy and reliability. HP Smart Array P800 Controller (381513-B21) supports Dual Domain on the MSA70 with the addition of the HP StorageWorks Dual Domain I/O Module in a single initiator environment. Requires Dual port SAS drives HP (AH303A) SC44Ge Host Bus Adapter supports Dual Domain on the MSA70 with the addition of the HP StorageWorks Dual Domain I/O Module in a Multi Initiator environment. Supports only HP-UX and Open VMS and on selected HP Integrity Servers only. NOTE: Drives in the bundles are Single Port drives only. HP StorageWorks Dual Domain MSA70 7.5TB DP SAS HDD Bundle (MSA70 w/25 300GB SFF DP SAS HDD + I/O Module) AP715A Part Number 418800-B21 AG779A
MSA70 Single Port drive Bundles MSA70 Dual Port drive Bundle
Step 2: Array Controllers
Smart Array Controllers Supported (Single Domain) Description HP ProLiant Servers HP Smart Array P800 controller HP Smart Array E500 controller HP Smart Array P600/256 BBWC Controller HP Smart Array P812 Controller/ 1G Flash Backed Cache Controller HP Smart Array P411/256MB Controller HP Smart Array P411/512MB BBWC HP Smart Array P212/256MB Controller HP Integrity Servers HP Smart Array P800 Controller HP Smart Array E500 Controller HP Smart Array P600/256 BBWC Controller NOTE: The HP Smart Array P800 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 50 drives in a 4U configuration behind each of the two external ports on the HP Smart Array P800 controller for a total of 100 drives in 4 enclosures. NOTE: Dual Domain is supported for the HP Smart Array P800 Controller (single initiator environment only) NOTE: The HP Smart Array P600 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 50 drives in a 2U configuration behind or the HP Smart Array P600 controller as the P600 has only a single external port. NOTE: The Smart Array E500 offers RAID 0, 1 and 1+0 and can be upgraded with DA - 12652 Worldwide Version 35 May 27, 2011 Part Number 381513-B21 435129-B21 337972-B21 487204-B21 462830-B21 462832-B21 462834-B21 AD335A AD226A 337972-B21
Page 13
SAS Controllers Supported (Dual Domain)
ProLiant server to RAID 5 with battery-backed write cache (BBWC) module - 383280B21. HP ProLiant Servers HP Smart Array P800 controller HP Integrity Servers HP SC44Ge Host Bus Adapter NOTE: Only HP-UX and Open VMS on selected HP Integrity servers supported. HP Integrity servers that are supported: rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards).
381513-B21 AH303A
Step 3: Choose Server(s)/MSA2000 G2/P2000 G3Arrays
Compatibility HP ProLiant Servers For up to date compatibility, please see the following URL for complete Smart Array P600, P800, E500, P411, P212 & P812 Controller compatibility and support information: http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html HP Integrity Servers HP Integrity Server rx2660 with combination PCIx/PCIe riser only HP Integrity Server rx3600 with combination PCIx/PCIe backplane only HP Integrity Server rx6600 with combination PCIx/PCIe backplane only HP integrity Server rx7640 with combination PCIx/PCIe only HP integrity Server rx8640 with combination PCIx/PCIe only HP integrity Server sx2000 with combination PCIx/PCIe only NOTE: HP Integrity Server home: http://www.hp.com/products1/serverconnectivity/support_matrices.html HP MSA2000 G2/P2000 G3 Arrays P2000 G3 home: www.hp.com/go/P2000 MSA2000 G2 home: www.hp.com/go/msa2000 NOTE: MSA70 is NOT supported behind a MSA2000 G2 (LFF) or a P2000 G3 (LFF)
Step 4: Choose Hard Drives
SAS Drives 6G SFF Serial Attached SCSI (SAS) Hard Drives HP 72 GB 6G SAS 15K 2.5 inch SFF DP ENT HDD HP 146 GB 6G SAS 10K 2.5 inch SFF DP ENT HDD HP 146 GB 6G SAS 15K 2.5 inch SFF DP ENT HDD HP 300 GB 6G SAS 10K 2.5 inch SFF DP ENT HDD HP 450 GB 6G SAS 10K 2.5 inch SFF DP ENT HDD HP 600 GB 6G SAS 10K 2.5 inch SFF DP ENT HDD HP 900 GB 6G SAS 10K 2.5 inch SFF DP ENT HDD NOTE: 6G drives will work in 3G systems like the MSA70. 6G drives will only function as 3G drives in a MSA70 NOTE: 450/600GB 6G SAS HDDs have not yet been qualified on the MSA2000 G2/P2000 G3 Arrays NOTE: In a single domain environment Dual Port (DP) drives will function as Single Port (SP) drives only. DA - 12652 Worldwide Version 35 May 27, 2011 512545-B21 507125-B21 512547-B21 507127-B21 581284--B21 581286--B21 619291-B21
Page 14
SAS Midline (MDL) SATA Drives
Cable Options
NOTE: Only Dual Port (DP) drives will work in the Dual Domain environment. Dual Domain environment requires the HP StorageWorks Dual Domain I/O Module Option (# AG779A). HP 1 TB 6G SAS 7.2K 2.5 inch SFF DP MDL HDD HP 500 GB 6G SAS 7.2K 2.5 inch SFF DP MDL HDD HP 1 TB 3G SATA 7.2K 2.5 inch SFF MDL HDD HP 500 GB 3G SATA 7.2K 2.5 inch SFF MDL HDD NOTE: SATA drives are not dual port (DP) drives. NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data Cables used for connecting the HP Smart Array P800/512 BBWC Controller (P/N 381513-B21 or AD335A ), the HP Smart Array E500 (P/N 435129-B21 or AH226A), the HP Smart Array P212 (P/N 462834-B21), the HP Smart Array P411 (P/Ns 462830-B21 or 462832-B21) or the P812 (P/Ns 487204-B21) to MSA70 Mini SAS 4x 2M Cable All Mini SAS 4x 4M Cable All Mini SAS 4x 6M Cable All NOTE: #0D1 will appear after this part number on your sales order if factory integration is indicated. Cables used for connecting the HP Smart Array P600/512 BBWC Controller (P/N 337972-B21) or the HP SC44Ge Host Bus Adapter (P/N AH303A) to MSA70 SAS 4x to Mini SAS 4x 2M SAS 4x to Mini SAS 4x 4M SAS 4x to Mini SAS 4x 6M NOTE: #0D1 will appear after this part number on your sales order if factory integration is indicated.
605835-B21 507610-B21 625609-B21 507750-B21
407339-B21 432238-B21 432239-B21
419571-B21 419572-B21 419573-B21
Step 5: Choose Rack Option
HP Universal Rack HP Universal Rack 10642 G2 Shock Rack HP Universal Rack 10642 G2 w/Ext Shock Rack HP Universal Rack 10636 G2 Pallet ALL HP Universal Rack 10636 G2 Shock Rack HP Universal Rack 10636 G2 Crated ALL HP Universal Rack 10636 G2 w/Ext Shock Rack HP 10642 G2 200mm Extn Shock Rack HP 10647 G2 200mm Extn Shock Rack HP Rack S10614 (14U) Rack Cabinet - Shock Pallet AF002A AF004A AF011A AF012A AF013A AF014A AF034A AF044A 292302-B22
HP Rack
Page 15
Family Comparison
Total Drive Count
Maximum Storage
Expansion Options Host Interface Drive Interface Drive Form Factor Clustering Support SAN Backup Support Storage Mirroring Support Systems Insight Manager Support OS Support
HP StorageWorks 50 Modular HP StorageWorks 60 Modular HP StorageWorks 70 Modular Smart Array Enclosure Smart Array Smart Array 10 SAS 12 SAS 25 SAS 10 SATA 12 SATA 25 SATA 10 SAS MDL 12 SAS MDL 25 SAS MDL 6TB SAS per enclosure or 5TB 24 TB per enclosure (using 2TB 22.5 TB SAS, or 25 TB SAS SAS MDL or SATA SATA disk drives) MDL or SATA MDL per enclosure None None None SAS SAS SAS SAS/SATA/SAS MDL SAS/SATA/SAS MDL SAS/SATA/SAS MDL 2.5 in. No No Yes Yes Windows, Linux, NetWare 3.5 in. HP-UX only No Yes Yes Windows, Linux, NetWare, SCO,HP-UX, Open VMS 2U 3-0-0 2.5 in. HP-UX only No Yes Yes Windows, Linux, NetWare, SCO, HP-UX, Open VMS, VMware 2U 3-0-0
Rack Height Warranty (parts/labor/onsite)
1U 3-0-0
Page 16
Technical Specifications
LED Indicators for HDDs Online (bottom) Drive failure LED (top) LED Indicators on Front Heartbeat LED Panel Fault LED UID LED LED Indicators on Rear I/O Module LED Panel UID button/LED Heartbeat LED Fault LED Power On/Standby button system Power supply LED Fan Module LED 4 x wide SAS 3Gb/s ports Up to 25 (twenty five) 2.5 inch SAS or SATA drives Operating Shipping
Host Interface Maximum Number of Drives Temperature Range
Relative Humidity Input Power Requirements
Heat Dissipation (maximum)
RAID Support
Upgradeable Firmware Disk Drives and Enclosure Protocol Support I/O Module
Operating Non-operating Rated Input Voltage Rated Input Frequency Rated Input Current Input Power (max) 1175 Btu/hr NOTE: Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration. See QuickSpecs for Smart Array Controllers P600, P800, E500, P212, P411 & P812 http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html MSA2000 G2: See Quickspecs for MSA2000 G2: www.hp.com/go/msa2000 P2000 G3: See Quickspecs for P2000 G3: www.hp.com/go/P2000 Yes, Offline only. Firmware updates available through hp.com HP 2.5 inch 3G SAS
50 to 95 F (10 to 35 C) -40 to 150 F (-40 to 66 C) NOTE: Rated 1C per 1000 feet of elevation to 10,000 ft. 10% to 90% Up to 95% 100 to 240 VAC 50 to 60 Hz 3.9A at 110 VAC typical, 6A Maximum 345 W
Connector Type Number of Ports Modular Smart Array 70 2U Rack Form Factor Cabinet Dimensions (HxWxD) Weight (Net) Weight (Gross)
IPass (mini-SAS) 4x (SFF8088) Two (one IN, other is OUT) 3.47 x 17.64 x 23.25 in (8.8 x 44.8 x 59 cm) 35 lb (15.9 kg) 48 lb (24.6 kg)
Page 17
Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
Page 18

Product End-of-Life Disassembly Instructions
Product Category: Storage Enclosures Marketing Name / Model [List multiple models if applicable.] HP StorageWorks MSA70 / 418800-B21
Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions for the disassembly of HP products to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE). 1.0 Items Requiring Selective Treatment 1.1 Items listed below are classified as requiring selective treatment. 1.2 Enter the quantity of items contained within the product which require selective treatment in the right column, as applicable. Quantity of items Item Description Notes included in product Printed Circuit Boards (PCB) or Printed Circuit Assemblies (PCA) Batteries Mercury-containing components Liquid Crystal Displays (LCD) with a surface greater than 100 sq cm Cathode Ray Tubes (CRT) Capacitors / condensers (Containing PCB/PCT) Electrolytic Capacitors / Condensers measuring greater than 2.5 cm in diameter or height External electrical cables and cords Gas Discharge Lamps Plastics containing Brominated Flame Retardants Components and parts containing toner and ink, including liquids, semi-liquids (gel/paste) and toner Components and waste containing asbestos Components, parts and materials containing refractory ceramic fibers Components, parts and materials containing radioactive substances EL-MF877-00 Template Revision A Include the cartridges, print heads, tubes, vent chambers, and service stations. 2 per each of 2 power supplies 2 AC, 2 PDU With a surface greater than 10 sq cm 1 I/O, 2 PS, 1 BP, 1 MP, 1 7-Seg All types including standard alkaline and lithium coin or button style batteries For example, mercury in lamps, display backlights, scanner lamps, switches, batteries Includes background illuminated displays with gas discharge lamps 0 0
Page 1
2.0 Tools Required List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed. Tool Description Tool Size (if applicable) Philips screw diver No. 1
3.0 Product Disassembly Process 3.1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment: 1. 2. 3. 4. 5. 6. 7. 8. 3.2 Optional Graphic. If the disassembly process is complex, insert a graphic illustration below to identify the items contained in the product that require selective treatment (with descriptions and arrows identifying locations). (see next page) Disassemble the power supply using No. 1 philips screw driver. Remove 2 electrolytic capacitors from each power supply.
EL-MF877-00 Template Revision A
Page 2
Location of the two capacitors to be removed in each power supply.
Page 3
Technical specifications
| General | |
| Device Type | Storage enclosure |
| Enclosure Type | Rack-mountable - 2U |
| Width | 17.6 in |
| Depth | 23.2 in |
| Height | 3.5 in |
| Weight | 35.1 lbs |
| Cabinet (Chassis) | |
| Built-in Devices | LED panel |
| Installed Devices / Modules Qty | 0 |
| Supported Devices / Modules Qty | 25 |
| Supported Drives | Serial ATA-300 / SAS 2 |
| Storage | |
| Max Supported Capacity | 7.5 TB |
| Hard Drive | |
| Type | Hot-swap - plug-in module |
| Capacity | 0 |
| Expansion / Connectivity | |
| Expansion Bays Total (Free) | 25 ( 25 ) x hot-swap - 2.5" SFF |
| Interfaces | 1 x Serial Attached SCSI ( input ) - 26 pin 4x Shielded Mini MultiLane SAS (SFF-8088) 1 x Serial Attached SCSI ( output ) - 26 pin 4x Shielded Mini MultiLane SAS (SFF-8088) |
| Miscellaneous | |
| Cables Included | 1 x Serial Attached SCSI cable - 1.6 ft |
| Rack Mounting Kit | Included |
| Power | |
| Power Device | 2 x power supply - hot-plug - plug-in module |
| Max Supported Qty | 2 |
| Power Redundancy | Yes |
| Power Redundancy Scheme | 1+1 |
| Voltage Required | AC 120/230 V ( 50/60 Hz ) |
| Manufacturer Warranty | |
| Service & Support | 3 years warranty |
| Service & Support Details | Limited warranty - parts - 3 years |
| Environmental Parameters | |
| Min Operating Temperature | 50 °F |
| Max Operating Temperature | 95 °F |
| Humidity Range Operating | 10 - 90% |
| Universal Product Identifiers | |
| Brand | Hewlett-Packard |
| Part Number | 418800-B21 |
| GTIN | 00882780564640, 04948382467881 |
Tags
PSR-64 XM-4S Nokia 2320 V-studio 100 E-330 Motorola V551 170X6FB M5630 Muvo N200 Priori XP 21FU1RK M 605 Spirit 500 C2556TN DSR-400K AJL308-37B AVX-P7000CD DVD-V6700S AS18fban S3000 Features 29FS4RK-LG X-750BF Star450-315 Manual NFG-DVI 8800 BPH WD-8003CH K790A 4015 Divx Scanmaker 6000 GX-F66RC HX6932 TX32LE8FA DP372B-N Lide 20 Travelpilot 300 ML-1665 Singer 269W Dect1222S-02 Turbotec SFC7-18 HD040GJ-P P50542 UT163 PLV55WM1 L14720 BJC-4200 7 6 VSX-516-S EX774N RT-40NZ60RB Decker 1000 Benq V772 7941G 32PF5521D ID 128 X-750 Ryobi 495 RMB-1075 Hv 5000 HTC VOX NS-C105 PSR-36 ZMC30QX UX-G60 MFC-6800 DCR-HC27E IC-E90 KRC-559R CH650 28PW6506-01 Recettes IG-A100 Matiz 1997088 Calor 5033 953BW EAH2400 Firmware Deluxe VGN-AR71S YP-S2QB IPF6100 DC500 Response 5690DN HT-S580 Driv3R 32LG50D Stylus D92 1200 S SX400 Zoom 1201 WD-1460FD CX-88 1215AC PL-Z93 GC8260 Alive 3 Specs PM0 4
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding