Reviews & Opinions
Independent and trusted. Read before buy Intermatic T104!

Intermatic T104

Manual

Download (English)
Instruction: After click Download and complete offer, you will get access to list of direct links to websites where you can download this manual.

About

Intermatic T104Intermatic T104 208-277-Volt DPST 24 Hour Mechanical Time Switch
This heavy duty mechanical time switch is designed for industrial, commercial and residential applications. This time switch has the highest horsepower ratings in the industry for loads up to 40 amps resistive from 120 to 480 volts providing direct 24 hour time switch control of most loads. This series provides 1 to 12 "ON/OFF" operations each day with minimum ON/OFF times of 1 hour. All models are equipped with one "ON" and one "OFF" tripper. FEATURES: TIMER SWITCH... Read more

Details
Brand: INTERMATIC
Part Numbers: 527912, T104
UPC: 00078275000025, 0078275000025, 078275000025, 78275000025

 

[ Report abuse or wrong photo | Share your Intermatic T104 photo ]

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

Document1

10/30/03

1:36 PM

Page 1

MODEL: T104

LR3730

24 HOUR DIAL TIME SWITCH

DOUBLE POLE SINGLE THROW (DPST)
40 AMP. RESISTIVE EACH POLE 120-480 VOLT AC; 40 AMP.INDUCTIVE OR TUNGSTEN OR 1000 VA PILOT DUTY EACH POLE 120V-277V AC; 2 HP (24 FLA)-120V AC; 5 HP (28 FLA)-240V AC.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO ORDER REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
TIME DIAL TIME POINTER OFF TRIPPER MANUAL LEVER WIRING DIAGRAM ON 2 WIRE TRIPPER 240 VGROUND AND A
GR 240V LINE 1 SUPPLY LINE 2 CLOCK MOTOR
CLOCK MOTOR: 208-277 VOLTS - 60 HZ.

TO LOAD(S)

GROUND
277/480 VOLT CONNECT MOTOR LEADS TO TERMINALS A AND 1 AND SUPPLY NEUTRAL TO TERMINAL A.
WIRING INSTRUCTIONS: To wire switch follow diagram above. Use solid or stranded COPPER only wire with insulation to suit installation. See gauge selection table for normal service applications. To make power connections remove 1/2 inch of insulation from wire ends. Insert bare ends of wire under the pressure plate of terminals. Use 3/16 or larger screwdriver to tighten terminal screws firmly. (25 lb-in minimum). REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.
MINIMUM COPPER WIRE SIZE (AWG) MAX. LOAD (AMP) MIN. INSULATION TEMP(C) 75C INSULATION MAX. MOTOR LOAD (HP) SINGLE PHASE 120 V. 240 V. 3 PHASE 208 V. 240 V.
PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE
PROGRAMMING INSTRUCTIONS 1. TO SET ON AND OFF TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL order 156T1978A. 2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact time-of-day on the CLOCKDIAL (the time now, when switch is being put into operation) to the pointer. DO NOT MOVE POINTER. OPERATING INSTRUCTIONS TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below CLOCK-DIAL left or right as indicated by arrows. This will not effect next operation. IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming instructions. INTERMATIC INCORPORATED

158TS10948

SPRING GROVE, ILLINOIS 60081-9698

doc1

How to operate and set T100 series timer T104 is 240Volt timer. T101 and T103 are 120Volt timers T100R series: the R stands for Raintight and door will have rubber gasket When you open the door, there should be piece of translucent plastic covering the wiring. As long as plastic cover is in place, it is safe to touch visible timer parts. If you have a child who might stick something into the timer, then lock timer door. As a general rule with electrical devices, do not stand on bare ground or wet surface or lean into or touch anything metal while working on timer. Put down dry boards. Same with your circuit breaker panel. The T104 yellow dial rotates just like a clock. The dial has ON and OFF trippers attached to outer edge of dial. As these trippers rotate around they move on-off lever that turns the pool pump or Load on and off. ON tripper moves lever one direction, and OFF tripper moves same lever other direction. The manual override lever clicks back and forth with audible sound each time tripper moves on-off lever. Move manual override back and forth and it will turn Load on and off. Override should snap crisp and clean. To set timer, lift and rotate dial until current time lines up with stationary silver pointer. Stationary silver pointer is pointed at 6:00.
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html http://waterheatertimer.org/Intermatic-trippers-and-parts.html

Replacement Trippers

Replacement WG series Clock motor

T101 timer

 

Technical specifications

Full description

This heavy duty mechanical time switch is designed for industrial, commercial and residential applications. This time switch has the highest horsepower ratings in the industry for loads up to 40 amps resistive from 120 to 480 volts providing direct 24 hour time switch control of most loads. This series provides 1 to 12 "ON/OFF" operations each day with minimum ON/OFF times of 1 hour. All models are equipped with one "ON" and one "OFF" tripper. FEATURES: TIMER SWITCH 40 Amp Gray UL & CSA listed Boxed 208-277 Volts Double Pole Single Throw

 

Tags

WD-12391TD 4501 MF Avsl 125 Priori XP X940E Office130 M1800R DSC-H9 L12720VIT CR-5130 X3350 Abuw606LTA0 Motorokr CMD-Z7 RE-450X W2261VG DES-1226G World Generation MDS-JB940 P3314 50PC1DR-UA DCS-3430 WD6400H1q-00 GL2200 HD-H1 0TGL Eight 1993 MT810 GCS632U Abit TH7 TX-21MD3 MDS-MX101 VE538 Nuvi 850 EX-P700 ONE XL VGN-TX3hp-W Syberia II Photosmart 1100 PRO M40X Kodak Z915 LP-M5600F Ergoracer GT SB-29 19PFL5522D IR2016 Digital Ex-d1 SG200E F-Z92L Mysterieuse MXT PRO Lecoaspira 690 WB500 RT3000 Fiat Qubo VGN-C1s-H J3600 HP-800 WPS54GU2 VPL-PX31 Vision Triton 500 TX-28PM1F AQ24B1QE WPS54G Wavecom WMO2 SG-9800 Workstation 120 100 Mechanical 2004 2141 S PX-2076 Oslo 502 LE20S81BX BT8030 Coolpix L11 8 V2 Feedback AQV12FCN VDR-D230 3G DS-10 Travelmate 2200 PCD-5H PCI IC-F3GT Dvcr-A500 PH301S MES-230 Slide 200 CFC705W ML-8300 BV9560B D26410 TH-46PY8P MX DUO JBL LX22 1000-1 CF-20D60 Nikkor

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101