Reviews & Opinions
Independent and trusted. Read before buy AKG C419!

AKG C419


Bookmark
AKG C419

Bookmark and Share

 

AKG C419About AKG C419
Here you can find all about AKG C419 like review and other informations. For example: microphone.

AKG C419 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a AKG C419 please write about it to help other people.
[ Report abuse or wrong photo | Share your AKG C419 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
AKG C419, size: 1.6 MB

 

AKG C419

 

 

Video review

kip rods tipper vid 4 bodhran series 2 akg mic

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

Wind Instrument Micromic Description
The AKG C 419 is response tailored for use with both brass and woodwind instruments. The gentle low frequency roll-off compensates for proximity effect and the high frequency boost adds presence and clarity. Its hypercardioid polar pattern gives the C 419 additional isolation from floor monitors and other instruments. The microphone is small, light weight, and can be easily clipped to the bell of an instrument. The flexible gooseneck allows for precise capsule placement, while the rubber-tipped clamp ensures secure mounting and protects the instrument from damage. The C 419 features a 10 ft. (3 meter) cable terminated with an XLR-M connector. It accepts phantom voltages over the range of 9 to 52 volts. The C 419 L is terminated with a TA3-F, mini-XLR connector compatible with AKG wireless bodypack transmitters or the optional, B 29 L battery operated phantom power supply.

Specifications

Transducer type: Frequency response Polar pattern: Impedance: Output connector: Sensitivity: Powering: Size: Net weight: Shipping weight: Standard accessory Condenser pressure gradient 20 Hz - 20 kHz Hypercardioid 200 ohms XLR, mini XLR (C419/L) 7 mV/Pa; -43 dB (re 1 V) Phantom powering from 9 to 52 Vdc (7.1 x 1.4) including clamp (180 mm x 35 mm) 5.1 oz. (141 g) 16.8 oz. (462 g) W 44 Windscreen

Features

External shock mounting for excellent isolation Rubberized clamp for simple and secure mounting Miniature gooseneck extension for precise placement Adaptable to phantom powering or wireless operation Hypercardioid pattern for good isolation from other players and floor monitors
Sound pressure level for 1% /3% THD: 126/130 dB
Optional Accessories: B 29 L Battery operated phantom power supply with a 2 input mixer. (used with the C 419 L version) WMS 40, 80, 61, 81 wireless microphone system (used with the C 419/L)
Architects and Engineers Specifications
The microphone shall be a condenser type with a hypercardioid pickup pattern with response from 20 Hz to 20 kHz. Sensitivity shall be no less than 7 mV/Pa, and the maximum operating level for 1 and 3% THD shall be 126 and 130 dB, respectively. The microphone shall be equipped with a rubberized clamp to facilitate attaching to the bell of a wind instrument without leaving a mark on the instrument. The microphone shall be adaptable to either phantom powering over the range from 9 to 52 Vdc, or for direct use with a wireless transmitter worn by the user. The microphone dimensions shall be 7.1 x 1.4 inches, including the clamp, and the net microphone weight shall be no greater than 5.1 ounces. The microphone shall be the AKG Acoustics Model C 419.

Graphical Data

AKG is constantly improving and modifying its products, therefore, specifications are subject to change without notice.

Limited Warranty

Valid only in the United States. AKG Acoustics warrants AKG products against defects in material or workmanship for a period of two years from the date of original purchase for use, and agrees to repair or, at our option, replace any defective unit without charge for either parts or labor. Important: This warranty does not cover damage resulting from accident, misuse or abuse, lack of reasonable care, the affixing of any attachment not provided with the product, loss of parts or connecting the product to any but the specified receptacles. This warranty is void unless service or repairs are performed by an authorized service center. No responsibility is assumed for any special, incidental
or consequential damages. However, the limitation of any right or remedy shall not be effective where such is prohibited or restricted by law. Simply take or ship your AKG product prepaid to our service department. Be sure to include your sales slip as proof of purchase date. (We will not repair transit damage under the no-charge terms of this warranty.) Note: No other warranty, written or oral is authorized by AKG Acoustics, Inc. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how long an implied warranty lasts, so the above exclusions and limitation may not apply to you.

Microphones Headphones Wireless Microphones Wireless Headphones Headsets Electroacoustical Components
AKG Acoustics GmbH Lembckgasse 2125, P.O.B. 158, A-1230 Vienna/AUSTRIA Tel: (43 1) 86 654-0*, Fax: (43 1) 86 654-516 Internet: http://www.akg.com AKG Acoustics; A Division of Harman Pro Germany Bodenseestrae 228, D-81243 Mnchen/GERMANY Tel: (089) 87 16-0, Fax: (089) 87 16-200 Arbiter Pro Audio Wilberforce Road, London NW9 6AX/ENGLAND Tel: (0181) 202 1199, Fax: (0181) Specifications subject to change without notice. AKG ACOUSTICS, U.S. 914 Airpark Center Drive Nashville, TN 37217, U.S.A. Tel: (615) 620-3800, Fax: (615) 620-3875 Studer Japan Ltd. 2-43-7, Uehara, Shibuya-ku, Tokyo 151-0064/JAPAN Tel: (813) 3465-2211, Fax: (813) 3465-2214 Erikson Pro Audio 620 McCaffrey, St-Laurent, Quebec, H4T 1N1, CANADA Tel: (514) 738-3000, Fax: (514) 737-5069 Internet: www.jam-ind.com/eriksonpro

DS-C 419

doc1

Last modification: items 31, 32 exchanged / Letzte nderung: Pos 31, 32 vertauscht

2579Z.

03/2006

C 419-L

2+3: red/rot 1:screen (blue) /Schirm (blau)
C 419B-lock C 419 C 419PP
tip/Spitze: red/rot sleeve / Hlse: screen (blue)/Schirm (blau)

C 419/WL900

inner contact/innerer Kontakt: red/rot outer contact /usserer Kontakt:screen (blue)/Schirm (blau)
_________________________________________________________________
AKG Acoustics GmbH, A Harman International Company, Lembckgasse 21-25, A-1230 Wien, Austria. Tel.: (431)86654-0, FAX: (431)86654-1514, service@akg.com, www.akg.com Page/Seite 1 /4
C 419B-lock C 419 C 419/WL900

Description

2579Z0001: A 2579Z0002: B 2579Z0003: C
Part Nbr. Bestellnr. 2575Z0002 2579M1001 2578M0101 2578M0102 2579M1002 2579M1003 2578Z1401 2578Z1501 2578Z1601 0099N1500 2578Z2701 2578Z0501 2578Z2801 2517K0011 1801Z6401 1802Z0701 0016E0269 0017E0340 9999N0535 2578Z1201 2578Z0301 0966D2500 2397M1011 2397M1022 0019E0124 0019E0132 2578M0301 2578M0202 2578M0205 1000N0014 1801Z6101 9999N0536 2578Z2301 2366Z1401 0016E0137 2366Z0801 2344Z0101 9110U3198 1603P0001 A B

C 419-L C 419PP

2579Z0005: D 2579Z0008: E

E Bezeichnung

Capsule Capsule housing, OLD Holder, OLD Holder Capsule housing, 16 cm Capsule housing, 18 cm Capsule cover Windscreen, front Windscreen, rear Screw EJOT 15x5 Tension relief NEW Cover, OLD Cover Cable, 3 meters, molded Cable, per meter Cable, per meter B-lock conn., solderable Mini XLR Connector Spring Washer Nut Screw M2,5x6 PCB.-Assembly New version, compatible Cable module Cable module Outer clamp, molded Inner clamp, molded Inner clamp, molded Cable tie Cable, per meter Spring Locking washer Sleeve Connector Grommet Windscreen Sticker "CE" Carrying bag

2.1 2.14

W44 ---
1 (1) (1) 1 (1) (1) 1*) 1 x 1 -
1 (1) (1) 1 (1) (1) 1 x 1 -
1 (1) (1) 1 (1) (1) 1 1,x -

(1) 1 1,1 x 1 1

Kapsel Kapselgehuse, ALT Halter, ALT Halter Kapselgehuse, 16 cm Kapselgehuse, 18 cm Kapseldeckel Windschutz, vorne Windschutz, hinten Schraube EJOT 15x5 Zugentlastung NEU Deckel, ALT Deckel Kabel, 3 m, umspritzt Kabel, Meterware Kabel, Meterware B-lock Stecker, ltbar Mini XLR- Stecker Feder Scheibe Mutter Schraube M2,5x6 Print, komplett

Neue Version, kompatibel

Kabelmodul Kabelmodul Auenklammer, umspritzt Innenklammer, umspritzt Innenklammer, umspritzt Kabelbinder Kabel, Meterware Feder Rastscheibe Hlse Stecker Tlle Windschutz Haftetikette "CE" Zipp - Tasche
Please note: Tension relief 7 (2578Z2701) can only be used along with housing 2 (2579M1002) + cover 11 (2578Z2801). Cover 2578Z0501 fits to housing 2579M1001 only. *) for replacement purposes
Achtung: Die Zugentlastung 7 (2578Z2701) passt nur zu Gehuse 2 (2579M1002)+Deckel 11 (2578Z2801). Deckel 2578Z0501 passt nur auf Gehuse 2578M1001. *) fr Ersatzzwecke
Connection of phantom adapter C 419PP
Anschlu des Phantomadapters

Page/Seite 2 /4

Please NEVER solder directly at the capsule without using some kind of heat-sink such as metal brackets or a suitable pair of pliers. Avoid excessive solder temperatures and solder times exceeding 2 seconds! Inside the housing 2 the cable is secured with special adhesive. When dis-assembling the microphone it might be necessary to cut off the cable where it enters the holder and remove the rest of the cable or cable coating with a little screwdriver. Careful removal of the cable residue with a drill might also lead to the expected result. After reinstalling the new cable please secure it to part 2 or 7 using Loctite IS 424 adhesive or any other equivalent cement. When connecting two-wire C 416 to PCB 2397M1022 use round pad for screen and square pad for red. The rectangular pad remains unused. For variation 1(A), 3(C) and 5(D) inside the plug the blue cable core (if there is one) has to be connected to screen.
Lten Sie bitte NIEMALS direkt an der Kapsel, ohne fr ausreichende Wrmeableitung gesorgt zu haben. Eine passend geformte Metallklammer oder eine geeignete Zange kann dazu dienen. Die Ltdauer sollte keinesfalls lnger als 2 Sekunden sein! Innerhalb des Gehuses 2 ist das Kabel durch einen Spezialkleber zugentlastet. Zum Kabeltausch kann es notwendig sei, das Kabel an der Eintrittstelle abzuschneiden und Reste von Kabel bzw. Kabelmantel mittels eines kleinen Schraubenziehers zu entfernen. Auch vorsichtiges Ausbohren wird zum gewnschtem Erfolg fhren. Beim Montieren des Kabels, bitte unbedingt auf richtige Klebung achten. Als Sicherungskleber eignet sich die Type IS 424 von Loctite oder ein vergleichbares Produkt. Bei Verwendung von C 416 mit Zweidrahtanschluss kommt der Schirm auf den runden Kontakt des Prints 2397M1022 und die rote Ader an den quadratischen Kontakt. Der rechteckige Kontakt bleibt frei. Bei Variante 1(A) 3(C) und D(5) muss im Stecker die blaue Ader - falls vorhanden - mit dem Schirm verbunden werden.

 

Tags

ICD-SX66 Motorola W180 DVR15 TDE4224 Euroset 3005 AES-FG Kw SA-AK47 File 2 GBS301 Motorola E1 Modulo CDX-GT444U LP225 Digimax 202 Thinkpad A22P SCX-3205 Impressa J7 MV6I MC Frontier Computer KX-TG8011GR Studio 32PFL5522D Dmcfz18 PLV-Z5BK DSC-H20 RX-CW55 ABM 4900 Leica Iiic 5-SUB Mk2 DWS684 Gr-d93 B2130 DVD-R1000 TX-21S4TP Form 20 SB-600 K8V-MX MH-6387TRC PB101 DLP-ITC250 Samsung T260 VGN-FZ11E Express 946 RM-S1AM E3200 Tensei-nocturne S2R 1000 Favorit 475I Samsung 701N Fp-IN9 SLI Blueberry WS-32Z409P KP125 UN46B8000XF X5340 MS-6712 ADC5105 Microphone Phase TWO VR3000-VR5000 HF370 LTV1090 BDM125S SWF-P8 IPF500 DG834GV4 AOM-711 BF641fstp Factory TZR50 DAB123 Speed 100 SRU1020 EWT1041 BT250 NV7-133R Universalis Ique 3600 XM-502X XL 1000 Motorazr V3 Animation 5 Dect1212S KX-TGA810E UF-332 MVX450 Pl CN Veva 1200 Slr-C 167MT DCR-PC115 RC-20XL Tester Bizhub C351 DVP-SR100 PSC 1215 Urct-48B BMW 740I PCG-FR315B

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101