Gardena C1060 Profi
|
|
Bookmark Gardena C1060 Profi |
About Gardena C1060 ProfiHere you can find all about Gardena C1060 Profi like solar and other informations. For example: .
Gardena C1060 Profi manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Gardena C1060 Profi please write about it to help other people. [ Report abuse or wrong photo | Share your Gardena C1060 Profi photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(Italian)Gardena C1060 Profi, size: 453 KB |
Download
(English)Check if your language version is avaliable. Most of manuals are avaliable in many languages. |
Gardena C1060 Profi
User reviews and opinions
| Peter |
10:27am on Monday, December 20th, 2010 ![]() |
| Instructions are highly complicated and confusing. I'd be very surprised if anybody actually got this thing to work. Definatly a don't buy. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents
GARDENA
Art. 1815
GB Operating Instructions Water Computer Profi C 1060 S Bruksanvisning Bevattningscomputer C 1060 Profi NL Gebruiksaanwijzing Besproeiingscomputer C 1060 Profi D Gebrauchsanweisung Bewsserungscomputer C 1060 profi FIN Kyttohjeet Kasteluohjain Profi C 1060
GARDENA Water Computer Profi C 1060
1. Notes on these Operating Instructions
3. Technical Data
Operating pressure: Flow medium: Max. water temperature: Number of program-controlled watering cycles per day: Watering time per program: Battery: Service life of the battery : 1-12 bar clean fresh water 40 C up to min. to 9 hrs 59 mins. 1 x 9 V alkali-manganese (alkaline) type IEC 6LR61 approx. 1 year
Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the Water Computer Profi, the unit's features and proper use as well as with the notes on safety. For safety reasons children and young people under 16 and anyone who is not familiar with these operating instructions may not use the Water Computer.
Keep these operating instructions in a safe place.
4. How the Water Computer Works
This GARDENA Water Computer Profi C 1060 allows you to water your garden completely automatically any time you choose up to 6 times a day, whether you are using a sprinkler, a sprinkler system installation or a drip-head watering system. Your Water Computer waters your garden completely automatically according to the program you choose. You can use your Water Computer to water your garden early in the morning or late at night when water evaporates the least or when you are on holiday. You simply program the watering start, watering time and watering day(s) or cycles.
2. Proper Use
The GARDENA Water Computer Profi C 1060 is suitable and determinated for private use in domestic and hobby gardens, exclusively for outdoor use, to control sprinklers and watering systems. The Water Computer must not be used for industrial purposes or in conjunction with chemicals, foodstuffs, easily flammable and explosive materials.
Compliance with the operating instructions provided by the manufacturer is a prerequisite for proper use of the GARDENA Water Computer. The operating instructions also contain operating, servicing and maintenance conditions.
5. Summary of Operating Instructions
1. Insert the Battery Only use a 9 V alkali-manganese (alkaline) battery type IEC 6LR61. Check the polarity (+ / markings). 2. Reset the Unit (delete data) Press the L and O.K. keys simultaneously for at least 2 seconds. All LCD symbols are briefly displayed. All previous programs are then deleted, the current data (time and day of the week), however, remain unchanged. 3. Programming You can move to the next program level by pressing the Menu key. You can confirm the data you have entered by pressing O.K. You can change the flashing data in the respective program level by pressing the L key. Menu
Time L L
6. Water Computer Function Keys / Display
6.1 Function Keys (Fig. C)
1L 2 O.K. 3 Menu 4 man On / Off
To change the individual input data (e.g. hours, minutes, days etc.) To quickly run through the data hold the key down. To confirm the data you have entered with L and to confirm the data displayed for a step of the program. To change to the next program level. To open and close the water flow independent of the program.
6.2 LCD Display (Fig. C)
Weekdays (Mo, Tu, etc.) Programs special
Displays the current weekday (current date / time) or the programmed watering days (watering programs). Displays the selected program (1- 6). To control the automatic water distributor exclusively, Art. No. 1198. Note : This function must not be selected unless you are using this product! Flashes in the input mode for the current data (hours, minutes, day of the week). Flashes in the input mode for the watering starting time. Appears with 12-hour clock model (e.g. USA, Canada) in the time from 12:00 noon to 12:00 midnight. Not displayed in AM cycle. Minute indicator Second indicator Hour indicator For current time and watering starting time. Flashes after the current data has been set / changed. For current time and watering starting time.
Current time Hour + minute Day of the week
O.K. O.K.
Programmed data
L L L L
Prog. 1 - 6 + special Watering starting time Hours + minutes Watering time Hours + minutes Watering cycle / days
TIME START PM
On / Off-Prog.
(TIME / START TIME)
4. Manual On/Off Operation Press the man On / Off key once to open the valve and press again to close to valve. The opening time is pre-set at the factory to 30 minutes but can be changed once the valve open by pressing the L key.
RUN TIME
Hour indicator Minute indicator
For watering time (RUN TIME). Flashes in the input mode. For watering time (RUN TIME). Flashes in the input mode.
Anti-theft protections (optional) With special one-way screw and bracket. Available from GARDENA Services. Release button To release the control unit.
Watering cycles (3rd, 2nd ) Displays the watering cycles set in the program mode: 3rd Watering every 3 days 2nd Watering every 2 days
6.4 Other Products Which can be Connected Fig. E Fig. F Fig. G GARDENA Soil Moisture Sensor (Art. No. 1187) GARDENA Rain Sensor (Art. No. 1189) GARDENA Automatic Water Distributor (Art. No. 1198)
Status indicator Off On No watering (e. g. during a rainy spell ) Watering programs running.
7. Preparation
1. Inserting the Battery (Fig. A) Only use a 9 V alkali-manganese (alkaline) battery type IEC 6LR61. Check the polarity (+ / markings). When using the Water Computer for the first time all LCD symbols light up for 2 seconds when the battery is inserted (Fig. 1). The unit is then ready for data input (Fig. 2).
Batt. appears in the LCD display if the battery power is too low. Change the battery! Error message appears when watering programs overlap. Only applies when using the special function.
6.3 More Functions
G H I J K L
Connection
For GARDENA Soil Moisture Sensor (Art. No. 1187) and GARDENA Rain Sensor (Art. No. 1189).
Battery compartment To insert a 9 V battery on the back of the control unit. Connection socket Socket to connect the control unit. Sleeve nut To connect the Water Computer to the tap.
Fig. 1 All LCD symbols
Fig. 2 Unit ready for data input
2. Connecting to the Tap The Water Computer is fitted with a sleeve nut for taps with 33.3 mm (G 1) thread. Adaptor for G 3 /4 thread (26.5 mm) The adaptor supplied allows the Water Computer to be connected to taps with a G 3 /4 thread (26.5 mm). If you are using the adaptor, screw the adaptor onto the tap before screwing the Water Computer onto the adaptor. Warning ! Attach and screw on manually. Do not use pliers !
G 3 /4 adaptor for sleeve nut To connect to taps with a G 3 /4 thread. GARDENA threaded tap connector Fits GARDENA System hoses.
8. Programming
Before you start entering the watering data in the computer we recommend that you write the data on one of the watering plans in the appendix to maintain more of an overview. Your watering plan could look like this:
Prog. Starting time START TIME Watering time RUN TIME Watering time / cycles Mo Tu We Th Fr Sa Su 2nd 3rd
5. Select the current weekday by pressing the L key, e.g. Sa for Saturday. 6. Confirm the data you have entered with O.K. and move to the next step of the program.
7 : : : : 00 : :
0 : : : : 15 : :
8.2 Entering the Watering Data (starting time, time, days) Prog. 1 - 6 or special : You can enter up to 6 watering programmes or select the special function. special function : The GARDENA Automatic Water Distributor Art. 1198 is required for the special function (see 14.2 Automatic Water Distributor). If you wish to select the special function, you must first reset the Water Computer:
You can now enter data by pressing the Menu key. Important : As shown in the diagram in Fig. B, the control unit can be removed from the housing to be programmed. To release the unit from the housing press the release button 8.1 Entering the Current Data (time / day) 1. Press Menu. Not necessary when using the Water Computer for the first time ! The hours and TIME flash. 2. Enter the hours, e.g. 9:00. Range: 0 - 23 3. Press O.K. to allow you to enter the minutes. 4. Set the minutes with the L key, e.g. 30. Press O.K. to allow you to enter the weekday. Monday (Mo) is followed by Tuesday (Tu), etc. 12
v Press the L and O.K. keys simultaneously.
1. Select the special function or the program with L, e.g. program 3. Press O.K. to confirm the data you have entered and move to the next program level.
2. Select the hour for the starting time using L (START TIME), e.g. 6. Confirm the data you have entered with O.K. and move to the next step of the program. Range: 0 - 23
3. Select the minutes for the starting time using L, e.g. 00. Confirm the data you have entered with O.K. and move to the next step of the program.
7. Select another program (see point 1.) or use Menu to go to On / Off-Prog.
Range:: 00 - 59 4. Enter the hours for the watering time (RUN TIME) using L, e.g. 0 hours. Confirm the data you have entered with O.K. and move to the next step of the program. Range: 0 - 9 5. Enter the minutes for the watering time using L, e.g.15 minutes. Confirm the data you have entered with O.K. and move to the next step of the program. 8.3 On / Off-Prog. With the On / Off program the garden is watered according to the weather. 1. Select the setting with L: On = Watering programs switched on. Off = Watering programs switched off, e.g. during a rainy spell.
2. Press O.K. to confirm the data entered and return to the normal mode.
Range: 00 - 59 The maximum watering time is 9 hours and 59 minutes. 6. Enter the watering days / cycles using L, e.g. water on Mondays (Mo) and Fridays (Fr). Confirm the data you have entered with O.K. and move to the next step of the program. 3rd: Watering every 3 days 2nd: Watering every 2 days
Note : You can select the next program level (current data, watering data, On / Off-Prog.) at any point during the programming sequence by pressing the Menu key. Data which you have not confirmed with O.K. will not be saved. If data is not entered within 60 seconds, the programming mode is closed automatically and the LCD shows the time (normal operation). You have now successfully programmed the Water Computer, i.e. the integrated valve opens and closes completely automatically and therefore waters the garden at the times which you have programmed.
Example : It is Saturday 6:05 am On / Off-Prog. is at On (watering desired). Expected watering time (RUN TIME) is 10 minutes. Dots between the time are flashing The clock is running. RUN TIME is counting down.
(Fig.: Display during automatic watering)
11. Manual Program-Independent On / Off Operation
11.1 Manual Watering Time (RUN TIME) The Water Computer can be operated manually at any time by pressing the man On / Off key 4. Pressing the key once opens the water flow. 0:30 RUN TIME appears in the LCD display. i.e. the watering time (RUN TIME) is 30 minutes. When the opening time (30 mins.) is over the valve closes. Setting at the Factory For safety reasons, the opening time is preset at the factory to 30 minutes but can be interrupted at any time by pressing the man On / Off key. Individual Setting In addition to the opening time of 30 minutes set at the factory it is also possible to set an individual opening time. 1. Press the man On / Off key. Valve opens. 2. Provided that RUN TIME is flashing the opening time can be changed as required from 0:00 to 0:59 using the L key. Note : If RUN TIME B is set to 0:00 the valve closes and remains closed even if the man On / Off switch is pressed (childproof). Changes to the opening time are saved, i.e. the changed time is valid for all manual value opening times in the future. 11.2 RESET Return to RUN TIME (factory preset) With RESET (setting all program data to zero) i.e. simultaneously pressing the L and O.K. keys for 2 seconds, the manual opening time of 30 minutes is reset. 11.3 Manual Opening / Closing of the Valve If the valve is opened automatically it can be closed prematurely at any time without altering the program data (starting time, watering time and watering days) by pressing the man On / Off key 4. If the valve was opened manually and a programmed watering starting time overlaps the manual opening time, the programmed starting time is suppressed. Example : The valve is opened manually at 9:00 am, the opening time is 30 minutes. A program with a starting time (START TIME) between 9:00 and 9:30 will in this case not run.
If the valve has been opened by the program, it can be closed at any time without altering the program data (starting time, watering time, and watering days) by pressing the man On / Off key 4.
9. Read / Change Program
You can run through the program levels to check the data you have entered by repeatedly pressing the Menu key and select and check the program steps by pressing O.K. Note : Values for watering days must be set again when passing them using the O.K. key. Old values are deleted ! You can change the watering programs as described under Programming.
10. Important Operating Information
With overlapping programs and identical watering days, the 1st watering starting time has priority and other programs are not initiated. Example : Program Watering starting time 4 : : 30 Watering duration 1: : 40 Watering days Mo Tu. X X X
The first program is run on Monday, the 2nd program is cancelled.
12. Battery
12.1 Status Indicator If the battery voltage falls below a certain level the Batt. indicator appears E. It is possible to initiate watering manually even if the battery capacity is too low (valve no longer opens), but programmed watering times, however, are not initiated. Even if the battery capacity is too low to run a program, if the valve is open it will be closed. The battery voltage is tested during the opening pulse. In this way you can test the capability of the battery at any time. To do this, simply press the On / Off key 4. If the valve opens and the Batt. indicator does not appear then the battery does not have to be changed. 12.2 Changing the Battery If the battery is changed within 1 minute the data you have entered is saved (program saved). When the battery is removed the display goes off and programs cannot be run while the battery is being changed. When the battery has been changed we recommend you check the data as described in Read / Change Program. If it takes longer than a minute to change the battery or if the battery power was already so low that there was no longer any opening pulse, the Water Computer must be manually reset (all program data set to zero). To do this, simultaneously press the L and O.K. keys. All the symbols appear on the LCD display. You must then reprogram the Water Computer. The current date / time which were previously displayed are saved.
.To prevent water penetrating the battery compartment, the Water Computer may only be installed in a perpendicular position with the sleeve nut pointing upwards.Program the Water Computer with the tap turned off. In this way you can avoid getting wet when trying out the manual On / Off function. You can remove the control unit from the housing to program the Water Computer.Only use the Water Computer outdoors. Warning ! The Water Computer must not be used indoors.The Water Computer must be stored in a dry place away from frost before the frosty season begins.The cover provided for the operating display must be used as shown in Fig. B. To protect the operating display against the weather the cover must be flipped over when you have finished programming the computer. Stick the programming help provided on the inside of the display cover.At high temperatures (over 60 C at the display) the LCD display may extinguish. This does not affect the program in any way. When the computer cools down the LCD display illuminates again.The max. temperature for the water flow is 40 C.The minimum operating pressure is 1 bar, the maximum operating pressure is 12 bar.Check the filter in the sleeve nut sary.
13. Notes on Safety and Operation
J regularly and clean if neces-
For safety reasons only a 9 V alkali-manganese battery (alkaline) type IEC 6LR61 must be used.
.Avoid tensile strain. Do not pull the hose connected to the Water Computer.Only use clear fresh water.
.The battery must be exchanged in time to prevent the Water Computer failing due to a low battery when you are away for longer periods of time. Make sure that the time the battery has been in operation and the time you are planning to be away does not add up to more than a year.The functional safety of the Water Computer depends on the capability of the battery. The Water Computer will only run for approx. a year if the alkali-manganese battery has a nominal voltage of at least 9 V. Check the battery before you buy it.
14. Options
14.1 Anti-Theft Protection (Fig. D) To protect your Water Computer against theft, the GARDENA anti-theft protection M (1815 - 00.791. 00) is available at GARDENA Service. The bracket on the anti-theft protection is fitted onto the back of the unit. Note that the screw included cannot be loosened once it has been screwed in. The bracket can be used, for example, to attach a chain.
14.2 GARDENA Automatic Water Distributor (Fig. G) Function Connecting the GARDENA Automatic Water Distributor (Art. No. 1198) allows you to control up to 6 watering lines with the Water Computer Profi C 1060. This is ideal where there is an insufficient amount of water or where individual areas of the garden have varying water requirements. It allows all watering lines to be operated one after another. Programming Using the special function, your Water Computer Profi C 1060 is able to take into account the special requirements of the Automatic Water Distributor, Art. No. 1198, when programming. Please pay attention to the following information: Please RESET the computer before setting the special function (by simultaneously pressing the L and O.K. keys). Note : To ensure the Automatic Water Distributor switches safely there must be at least 30 minutes between the programs entered in the Water Computer. Include breaks. When you have confirmed the special function with O.K. and have entered the data for the first program (see Programming chapter) all the programmes which follow will be pre-programmed automatically. The pre-programming takes into consideration the 30 minute break required between the programs as well as a minimum watering time of 30 seconds (display: 1 min.). This watering time is required to allow the Automatic Water Distributor to switch to the next outlet and to ensure that the order of the watering programs to the appropriate watering line is retained. The watering days entered for the watering program are valid for all other watering programs. Error Message (ERROR) You can alter the watering starting times and watering times pre-programmed by the Water Computer to meet your personal requirements. However, if you do not take into account the break times mentioned above, any changes you make are not accepted and an error message appears on the display (ERROR). RESET Function Since it is very easy for watering times to overlap slightly, especially when the beginnings and ends of programs are very close together, it is sensible to RESET the Water Computer (simultaneously press the L and O.K. keys) and to re-enter the watering data to prevent an error message appearing. 20
On / Off-Prog. If the watering programs are switched off after you have confirmed the special function (status indicator on Off-Prog.) all the programs which begin in this time are shortened to the minimum watering time of 30 seconds (display: 1 min.) This ensures that the order of the watering programs to the appropriate outlet of the Automatic Water Distributor is retained. By briefly opening the water flow the outlets on the automatic water distributor are switched further so that when the watering programs are reactivated (status indicator on On-Prog.) the original order of the outlets for the required watering program is retained. Soil Moisture Sensor, Rain Sensor When using the Water Computer Profi C 1060 together with the Automatic Water Distributor (Art. No. 1198), Soil Moisture Sensor (Art. No. 1187) or Rain Sensor (1189) please note the following: If the special function is activated and the Soil Moisture or Rain Sensor indicates sufficient moisture, watering is interrupted. The watering time of following watering programs is shortened to 30 seconds (display: 1 min.) until the Soil Moisture / Rain Sensor allows the watering programs to be resumed. The watering time originally entered then begins. Shortening the watering time when the soil is sufficiently moist ensures that the automatic water distributor is switched to the next outlet and therefore ensures that the correct order of the watering program for the respective distributor outlet is retained. 14.3 GARDENA Soil Moisture Sensor (Fig. E) Together with the GARDENA Soil Moisture Sensor (Art. No. 1187) watering is controlled considering the soil moisture. Assembly The Soil Moisture Sensor is connected to the socket control unit (Fig. A).
G on the back of the
How it Works If the connected Soil Moisture Sensor indicates there is sufficient moisture then the watering program is either interrupted or not initiated. Note: Watering can still be initiated manually by pressing the man On / Off key. 14.4 GARDENA Rain Sensor (Fig. F) Together with the GARDENA Rain Sensor (Art. No. 1189) watering is controlled considering natural precipitation.
Assembly The Rain Sensor, as an alternative to the Soil Moisture Sensor, can be connected to the connection socket G on the back of the control unit (Fig. A). How it Works If the connected Rain Sensor indicates an appropriate amount of rain, the watering program is interrupted or not initiated. Note : Watering can still be initiated manually by pressing the man On / Off key.
Watering not initiated.
Watering data (starting time / duration / days) not complete. On / Off-Prog. active set to Off. Data input / changes made while the program was starting or immediately before. Valve was opened by manual On, program is not executed. Tap turned off.
Check data and complete if necessary. Restart the program: Set to On (see On/Off-Prog.). Input / change data before or after the set start times.
15. Faults
Fault LCD display not lit. Possible Cause Battery inserted incorrectly Flat battery. Remedy Check + / markings. Insert a new alkaline battery and test by pressing the man On / Off key. Display illuminates again when temperature falls, test function by pressing man On / Off. Set current data.
Turn on tap. Re-enter data, eliminate program overlaps.
Programs overlap: 1. START TIME has priority, other programs are not run. Soil Moisture Sensor indicates sufficient moisture. Battery flat after working for a short time. Undefined LCD display after battery has been changed. Not an alkaline battery. Battery was not changed within a minute or the battery was already run down so that there was no longer an opening pulse.
Temperature at display is above 60 C.
If dry, check setting / position of the Soil Moisture Sensor. Use an alkaline battery. RESET the water computer by simultaneously pressing the L and O.K. keys. Re-enter data as described.
Not able to enter watering data (hours / minutes / starting time / time / days). Not able to open manually using man On / Off key.
Current data hours, (minutes / day) not complete.
Weak battery, Batt. indicator appears. Manual On Time set to 0:00. Tap turned off.
Insert a new alkaline battery. Set manual On time. Turn on tap. Insert a new alkaline battery.
If you have any problems with your Water Computer, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet. If covered under warranty, please include the completed and signed warranty card. 23
Watering not initiated. 22
Weak battery, Batt. indicator appears.
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
EU Certificate of Conformity
The undersigned GARDENA Kress + Kastner GmbH Hans-Lorenser-Str. 40 D-89079 Ulm hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit is modified without our approval. Description of the unit: Water Computer Type: Profi C 1060 Art. no.: 1815 EU directives: Electromagnetic Compatibility 89 / 336 / EC Directive 93 / 68 / EC Thomas Heinl Technical Dept. Manager Year of CE marking: 1998 Ulm, 17.07.1998
Guarantee
GARDENA guarantees this product for 12 months (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply:.The unit must have been handled properly and in keeping with the requirements of the operating instructions. Neither the purchaser nor a non-authorised third party have attempted to repair the unit.The unit has been returned directly to a GARDENA Service Centre, postage paid, together with the completed and signed warranty card and proof of purchase. This manufacturers guarantee does not affect the users existing warranty claims against the dealer / seller. Defects in the Water Computer attributable to batteries which have been incorrectly installed or are leaking are excluded from the warranty provisions.

Also use Google-translate and ImTranslator to help translate web content including manuals S FIN
GB Operating Instructions Water Computer Profi S Bruksanvisning Bevattningscomputer NL Gebruiksaanwijzing Besproeiingscomputer D Gebrauchsanweisung Bewsserungscomputer FIN Kyttohjeet Kasteluohjain
GARDENA
C 1060 profi Art. 1815
Gardena manuals on following link. http://waterheatertimer.org/How-to-program-Gardena-C1060.html
GARDENA Water Computer C 1060 profi
Welcome to the Garden of GARDENA.
Please read these operating instructions carefully and observe the notes given. Use these instructions to familiarise yourself with the Water Computer and its proper use as well as the notes on safety. For safety reasons, children and young people under 16 as well as anyone who is not familiar with these operating instructions must not use the Water Computer.
9. Putting Your Water Computer out of Operation. 25 10. Accessories. 25 11. Technical Data. 26 12. Service. 27
1. Where to Use Your GARDENA Water Computer
Intended use
The GARDENA Water Computer C 1060 profi is intended for private use in domestic and hobby gardens, exclusively for outdoor use, to control sprinklers and watering systems. The GARDENA Water Computer must not be used for industrial purposes or in conjunction with chemicals, foodstuffs, easily flammable and explosive materials.
Please note
Contents
v Please keep these operating instructions in a safe place. 1. 2. 3. 4. 5. 6. 7. 8. Where to Use Your GARDENA Water Computer. 3 For Your Safety. 3 Function. 5 Putting Your Water Computer into Operation. 8 Programming. 11 Automatic Water Distributor (optional). 19 Cleaning. 22 Trouble-Shooting. 22
2. For Your Safety
Battery:
To ensure the Water Timer runs safely, only a 9 V alkaline manganese battery (alkaline) type IEC 6LR61 must be used.
The battery must be exchanged in time to prevent the Water Computer failing due to a low battery when you are away for longer periods of time. Make sure that the time the battery has been in operation and the time you are planning to be away does not add up to more than a year.
Setting up
Warning ! The Water Computer must not be used indoors. v Only use the Water Computer outdoors. The Water Computer may only be set up vertically with the sleeve nut to the top to prevent water penetrating into the battery compartment. The minimum water output to ensure that the Water Computer functions correctly is 20 - 30 l / h. For example, at least 10 x 2-litre Drip Heads are required to control the Micro-Drip-System. At high temperatures (over 60 C at the display) the LCD display may extinguish. This 4
does not affect the program in any way. When the computer cools down the LCD display illuminates again. The max. temperature for the water flow is 40 C. v Only use clear fresh water. The minimum operating pressure is 0,5 bar, the maximum operating pressure is 12 bar. Avoid tensile strain. v Do not pull the hose connected to the Water Computer.
3. Function
This GARDENA Water Computer C 1060 profi allows you to water your garden completely automatically any time you choose up to 6 times a day, whether you are using a sprinkler, a sprinkler system installation or a drip-head watering system. Your Water Computer waters your garden completely automatically according to the program you choose. You can use your Water Computer to water your garden early in the morning or late at night when water evaporates the least or when you are on holiday. You simply program the watering start, watering time and watering day(s) or cycles.
Programming v Program the Water Computer with the tap turned off. In this way you can avoid getting wet when trying out the manual On / Off function (man. On / Off). You can remove the control unit from the housing to program the Water Computer.
Key-operated functions
Key-operated function Changes or moves on the input data. (If the -key is held down, the figures change very quickly.) Confirms the values set with the -key. Changes to the next program level. For switching the water throughput on or off manually.
2 O.K. 3 Menu 4 man.
On / Off
Displays
Display
Description
F Batt.
0 A 7 C
A B C D E
Weekdays Current weekday or programmed watering days. (Mo, Tu,.) Prog. Program selected (1 to 6). special Only for controlling the Automatic Water Distributor Art.-No. 1198. time Flashes when in input mode for the current data (hours, minutes, day of the week). START Flashes when in input mode for watering start time. PM Display for 12-h-clock (e. g. in USA, Canada). (Time / Current time / Watering start time Start time) (display 13 h = 1 pm ; e. g. in USA, Canada). R U N T i m e Watering time (flashes when in input mode). 3 rd, 2 nd Watering cycles (3 rd every 3 rd day / 2 nd every 2 nd day). % RunBudget function: the watering time of all watering Time programs can be reduced centrally in intervals of 10 % from 100 % to 0 %. ERROR Error message for the special function if watering programs overlap.
G Prog.
If the battery indicator begins to flash, the battery is almost flat and watering programs will no longer run. Any valves that are still open are closed again even if the battery is almost flat. The battery indicator is reset as soon as you replace the battery with a new one. Watering program inactive (Budget function: 0 %)
Display levels
The four display levels Level 1: Normal display Level 2 : Enter the current time and day of the week Level 3 : Insert watering programs Level 4 : % Run-Time / Prog. Off can be selected one after the other by pressing the Menu-key. You can change display level at any time, even during programming. All the program data which have been confirmed up to that point with the O.K.-key are stored.
4. Putting Your Water Computer into Operation
Insert battery:
This Water Computer must only be powered by a 9 V alkaline manganese (alkaline) battery type IEC 6LR61. 1. Press unlock button H and pull control unit I out of the Water Computer housing. 2. Insert battery J into battery compartment. Ensure that the battery polarity P is correct. The display shows all the LCD-symbols for 2 seconds and then moves to the time / day of week level. 3. Re-insert control unit I in housing. D z Programming aid : v Stick the self-adhesive programming aid on the inside of the display cover D. The display cover can be folded up to protect the display against the weather.
Connect Water Computer :
The Water Computer is fitted with a sleeve nut L for taps with G 1 (33.3 mm) thread. The adaptor supplied K allows the Water Computer to be connected to taps with a G 3 /4 thread (26.5 mm). Connect Water Computer to water tap with G 1 (33.3 mm) thread : 1. Screw sleeve nut L of the Water Computer on to the tap thread by hand (do not use pliers). 2. Screw tap connector M on to the Water Computer. Connect Water Computer to tap with G 3 /4 (26.5 mm) thread : 1. Screw adaptor K on to the tap manually (do not use pliers). 2. Screw sleeve nut L of the Water Computer on to the adaptor thread K by hand (do not use pliers). 3. Screw tap connector M on to the Water Computer.
Compile watering plan :
Before you start entering the watering data in the computer we recommend that you write the data on one of the watering plans in the appendix to maintain more of an overview.
Example : Program PROG Starting time START TIME Watering time RUN TIME Mo Watering days / Watering cycles Tu We Th Fr Sa So 2 nd 3 rd
Fit anti-theft device (optional) :
7: : : : 00
0 : : : : 15
To secure your Water Computer against theft, you can obtain the GARDENA anti-theft device art. no. 1815-00.791.00 from GARDENA Service. 1. Screw clamp O with screw P firmly to the back of the Water Computer. 2. Use clamp e.g. for fixing a chain. It is no longer possible to remove the screw after it has been screwed in.
O 5. Programming
The control unit I can be removed from the housing for programming by pressing the unlock button H and programming can be undertaken whilst you are moving around (see 4. Putting Your Water Computer into Operation Insert battery ).
Connect soil moisture or rain sensor (optional) :
In addition to time-based watering, it is also possible to include the soil moisture or rain sensor in the watering programs. If the soil is moist enough, the program will be stopped, or a program will be prevented from starting. Manual operation via man. On / Off is unaffected by this.
1. Place soil moisture sensor in the watered area or place rain sensor (with extension cable if necessary) outside the watered area. 2. Insert the sensor in the sensor connection N of the Water Computer.
Set current time and day of week :
1. Press Menu-key (not necessary if the battery has just been inserted).
The hours display and t i m e flash.
2. Set the time in hours with the -key (example: 9 hours) and confirm with the O.K.-key.
1. Press Menu-key twice (not necessary if the current time and day of the week has been entered).
t i m e and the minutes display flash.
3. Set the time in minutes with the -key (example: 30 minutes) and confirm with the O.K.-key.
Program memory setting 1 flashes.
2. Only if the Automatic Water Distributor is used : Select special-function with the -key and confirm with the O.K.-key (continue with step 4).
t i m e and the day of the week display flash.
4. Set the day of the week with the -key (example: Sa Saturday) and confirm with the O.K.-key.
Program memory setting 1 is selected automatically, s t a r t t i m e and the hours section flash on the display.
3. Select program memory setting with the -key (example: Prog. 3 program 3) and confirm with the O.K.-key.
4. Enter watering programs :
The display moves to the message Insert watering programs and program memory setting 1 flashes. 3.
You must reset your Water Computer before selecting the special function (see 6. Automatic Water Distributor). v Reset : Keep -key and O.K.-key pressed simultaneous for 2 seconds. Up to 6 watering programs can be inserted or the special function can be selected.
s t a r t t i m e and the hours section flash on the display.
4. Set the hours for starting the watering time with the -key (example: 6 hours) and confirm with the O.K.-key.
s t a r t t i m e and the minutes section flash on the display.
5. Set the minutes for starting the watering time with the -key (example: 20 minutes) and confirm with the O.K.-key.
R U N T I M E and the hours for the watering time flash on the
5. display.
6. Set the hours for the watering time with the -key (example: 0 hours) and confirm with the O.K.-key.
8. (b)
8. (b) Select respective watering days with the -key (example: Mo, Fr Monday and Friday) and confirm with the O.K.-key. Press -key until the over Su disappears. The display returns to step 3 and the next highest program memory setting flashes. V If you would like to water your garden every day, press the OK button to confirm each day one after another. When the program has been created for program memory setting 6, the display moves to the message % Run-Time / Prog. Off.
R U N T I M E and minutes for the watering time flash on the
6. display.
7. Set watering time minutes with the -key (example: minutes) and confirm with the O.K.-key.
Activate watering programs :
You must select the Run-Time percentage you wish to activate before the watering programs can run. 9. Press Menu-key 3 times (not necessary if the program has just been compiled for program memory setting 6). 10. Select the percentage (see Budget Function) for the programmed watering time using the key (e.g. 60 % Run-Time) and then confirm your selection by pressing the O.K. key. The display moves to the normal display. Programming the Water Computer has now been completed, i.e. the built-in valve opens / closes entirely automatically and thus undertakes watering at the programmed times.
Watering cycle 3 rd flashes on the display. 7.
8. (a) Select watering cycle with the -key (example: 2 nd ) and confirm with the O.K.-key (2 nd / 3 rd : watering every 2 nd day / 3 rd day). The display returns to step 3 and the next highest program memory setting flashes.
or 15
Programmed watering time
Budget-Function (% Run-Time) : The times of all stored watering programmes can be reduced centrally in intervals of 10 %, from 100 % down to 10 %, without having to change each interval programme. This is ideal if you wish to water your garden less in the Autumn than in the Summer.
1. Press man. On / Off-key to open the valve manually (or to close an open valve). R U N T I M E and the watering time in minutes (set to 30 minutes in the works) flash for 5 seconds on the display. 2. Whilst the watering time in minutes is flashing, the watering duration can be modified with the -key (between 0 : 00 and 0 : ) (example: minutes). The valve is opened. 3. Press man. On / Off-key to close the valve early. The valve is closed. The amended manual opening period is stored, i.e. each time the valve is opened manually in future the modified opening period is preset. If the manual opening period is amended to 0 : 00 , the valve is closed and also remains closed after the man. On / Off-key is pressed (child lock). If the valve has been opened manually and a programmed start of a watering period overlaps the manual opening period, the programmed starting time is suppressed. Example : The valve is opened at 9.00 a.m. manually, the opening period is 30 minutes. A program with a start time (START TIME) between 9.00 and 9.30 a.m. will not be undertaken in this case. 17
Watering program deactivated
10 - 100 0
% Run-Time = Watering program active Prog. Off = Watering program inactive
Note : If you change the watering time percentage, your Water Computer will still display the watering time you originally programmed for the individual watering programs.
Read / modify watering programs :
If a program has already been set on one of the 6 program memory settings, this can be modified without having to compile it from the beginning again. 1. Press Menu-key twice. Program memory setting 1 flashes. 2. Press O.K.-key to move to the next program step or modify program data with the -key and confirm with the O.K.-key. The valve can be opened or closed manually at any time. A program-controlled open valve can also be closed early without changing the program data (start time, watering duration and watering days).
Manual operation :
The factory settings are restored. v Press -key and O.K.-key simultaneously for 2 seconds. All the LCD symbols are displayed for 2 seconds and the display moves to the normal display. All the program data are set to zero. The manual watering period is set to 0 : 30 again. The time and day of the week are retained.
6. Automatic Water Distributor (optional)
Function
Connecting the GARDENA Automatic Water Distributor (Art. No. 1198) allows you to control up to 6 watering lines with the Water Computer C 1060 profi. Each of the 6 watering lines can only be actuated once a day. This is ideal where there is an insufficient amount of water or where individual areas of the garden have varying water requirements. It allows all watering lines to be operated one after another. Using the special function, your Water Computer C 1060 profi is able to take into account the special requirements of the Automatic Water Distributor, when programming. If program data have already been inserted beforehand, a RESET must be undertaken before the special function can be set. v Keep -key and O.K.-key pressed simultaneously for 2 seconds. To ensure the Automatic Water Distributor switches safely there must be at least a 30 minute break between the programs entered in the Water Computer. When you have confirmed the special function with O.K. and have entered the data for the first program (see 5. Programming ) all the programmes which follow will be pre-programmed automatically. 19
Important notes :
If no entry is made during programming for a period of more than 60 seconds, the normal display reappears.
Programming
With overlapping programs and identical watering days, the 1st watering starting time has priority and other programs are not initiated. Example : Program PROG Starting time START TIME Watering time RUN TIME Mo Watering days / Watering cycles Tu We Th Fr Sa So 2 nd 3 rd
Special function
4 : : 30
0: : 00
The first program is run on Monday, the 2 nd program is cancelled. 18
The pre-programming takes into consideration the 30 minute break required between the programs as well as a minimum watering time of 30 seconds (display: 1 min.). This watering time is required to allow the Automatic Water Distributor to switch to the next outlet and to ensure that the order of the watering programs to the appropriate watering line is retained. The watering days entered for the watering program are valid for all other watering programs.
By briefly opening the water flow the outlets on the Automatic Water Distributor are switched further so that when the watering programs are reactivated (% Run-Time) the original order of the outlets for the required watering program is retained.
Soil Moisture Sensor / Rain Sensor
Error message ( E R R O R )
You can alter the watering starting times and watering times pre-programmed by the Water Computer to meet your personal requirements. However, if you do not take into account the break times mentioned above, any changes you make are not accepted and an error message appears on the display ( E R R O R ). Since it is very easy for watering times to overlap slightly, especially when the beginnings and ends of programs are very close together, it is sensible to RESET the Water Computer and to re-enter the watering data to prevent an error message appearing. If the watering programs are switched off after you have confirmed the special function (status indicator on Off Prog.) all the programs which begin in this time are shortened to the minimum watering time of 30 seconds (display: 1 min.) This ensures that the order of the watering programs to the appropriate outlet of the Automatic Water Distributor is retained.
When using the Water Computer C 1060 prof together with the Automatic Water Distributor, Soil Moisture Sensor (Art. No. 1187) or Rain Sensor electronic (Art. No. 1189) please note the following : If the special function is activated and the Soil Moisture or Rain Sensor indicates sufficient moisture, watering is interrupted. The watering time of following watering programs is shortened to 30 seconds (display: 1 min.) until the Soil Moisture / Rain Sensor allows the watering programs to be resumed. The watering time originally entered then begins. Shortening the watering time when the soil is sufficiently moist ensures that the automatic water distributor is switched to the next outlet and therefore ensures that the correct order of the watering program for the respective distributor outlet is retained.
On / Off Prog.
7. Cleaning
Clean filter :
The filter should be checked regularly and cleaned when necessary. 1. Unscrew sleeve nut L of the Water Computer by hand from the tap thread (do not use pliers). 2. Remove filter from sleeve nut L and clean. 3. Screw sleeve nut L of the Water Computer back on to the thread of the tap by hand (do not use pliers).
Fault No display appears
Possible Cause Temperature on the display is higher than 60 C.
Remedy Display appears after temperature has dropped. v Check function by operating manually. (man. On / Off). v Enter time and day of week (see 5. Programming). v Insert new (alkaline) battery v Set manual watering period to a figure greater than 0 : (see 5. Programming). v Turn tap on. v Read off watering program and modify if necessary. v Activate program (% Run-Time). v Make program entry / modification outside the programmed start times.
Programs cannot be entered Manual opening via the man. On / Off-key is not possible
The current time and the day of the week were not entered completely. Low battery power, Batt. indicator flashes Manual watering period is set to 0 : 0 0. Tap turned off.
8. Trouble-Shooting
Fault No display appears Possible Cause Battery inserted incorrectly. Flat battery. Remedy v Check polarity markings match (+ / ). v Insert new (alkaline) battery. v Check function by operating manually (man. On / Off).
Watering program is not being undertaken (no watering)
Watering program has not been entered completely. Programs deactivated (Prog. Off). Program entry / modification during or just before the start pulse.
Fault Watering program is not being undertaken (no watering)
Possible Cause Valve was opened manually previously. Tap turned off. Program overlap (1st watering start time has priority). Soil moisture or rain sensor reports sufficient moisture. Batt. indicator flashes because battery is almost flat.
Remedy v Avoid possible program overlaps. v Turn on tap. v Enter new watering program without overlaps. v If dry, check setting / location of soil moisture / rain sensor. v Insert new (alkaline) battery v Connect more drip heads
9. Putting Your Water Computer out of Operation
Over-wintering / storage :
1. Press Menu-key 3 times, select Prog. Off with the -key and confirm with the O.K.-key. The watering programs are deleted. 2. Store your Water Computer in a dry place where it is protected from frost. Please return flat batteries to a GARDENA dealer or dispose of them properly at your nearest recycling centre. Only dispose of batteries when they are flat.
10. Accessories
Automatic control with : GARDENA Soil Moisture Sensor GARDENA Rain Sensor electronic Art. No. 1187 Art. No. 1189 Art. No. 1198
Water Computer does not close
Minimum quantity of water drawn is less than 20 l / h.
If you have any other problems with your Water Computer, please contact GARDENA Service.
GARDENA Automatic Water Distributor
11. Technical Data
Min. / max. operating pressure : Flow medium : Max. medium temperature : Number of program-controlled watering cycles per day : Watering duration per program : Battery required : Operating time of the battery 0,5 bar / 12 bar Clear fresh water 40 C Up to min. to 9 hours 59 min. V alkaline manganese (alkaline) battery type IEC 6LR61 approx. 1 year
12. Service
Warranty
GARDENA guarantees this product for 2 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply: The unit must have been handled properly and in keeping with the requirements of the operating instructions. Neither the purchaser or a non-authorised third party have attempted to repair the unit. Damage caused by frost is not covered by the warranty. This manufacturers guarantee does not affect the users existing warranty claims against the dealer / seller. If you have any problems with your Water Computer, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet.
G S N D
Product Liability We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories. Produktansvar Tillverkaren r inte ansvarig fr skada som orsakats av produkten om skadan beror p att produkten har reparerats felaktigt eller om, vid reparation eller utbyte, andra n Original GARDENA reservdelar har anvnts. Samma sak gller fr kompletteringsdelar och tillbehr. Productaansprakelijkheid Wij wijzen er nadrukkelijk op, dat wij op grond van de wet aansprakelijkheid voor producten niet aansprakelijk zijn voor schade ontstaan door onze apparaten, indien deze door onvakkundige reparatie veroorzaakt zijn, of er bij het uitwisselen van onderdelen geen gebruik gemaakt werd van onze originele GARDENA onderdelen of door ons vrijgegeven onderdelen en de reparatie niet door de GARDENA technische dienst of de bevoegde vakman uitgevoerd werd. Ditzelfde geldt voor extra-onderdelen en accessoires. Produkthaftung Wir weisen ausdrcklich darauf hin, dass wir nach dem Produkthaftungsgesetz nicht fr durch unsere Gerte hervorgerufene Schden einzustehen haben, sofern diese durch unsachgeme Reparatur verursacht oder bei einem Teileaustausch nicht unsere Original GARDENA Teile oder von uns freigegebene Teile verwendet werden und die Reparatur nicht vom GARDENA Service oder dem autorisierten Fachmann durchgefhrt wird. Entsprechendes gilt fr Ergnzungsteile und Zubehr.
Product Liability Painotamme tuotevastuulain mukaisesti erityisesti sit seikkaa, ett emme vastaa elektroniselle vesiajastimelle aiheutuneista tai sen aiheuttamasta vahingoista, mikli ne ovat aiheutuneet epptevn korjauksen takia, mikli elektroniseen vesiajastimeen on vaihdettu osia, jotka eivt ole alkuperisi GARDENA-osia tai meidn hyvksymi osia tai mikli korjauksen on tehnyt jokin muu kuin GARDENA-huolto tai valtuutettu huolto. Sama koskee mys lislaitteita ja -varusteita.
EU Certificate of Conformity
The undersigned GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, hereby certifies that, when leaving our factory, the unit indicated below is in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit is modified without our approval.
EU Tillverkarintyg
Undertecknad firma GARDENA International GmbH, Hans-Lorenser-Str. 40, D-89079 Ulm, intygar hrmed att nedan nmnda produkter verensstmmer med EU:s direktiv, EU:s skerhetsstandard och produktspecifikation. Detta intyg upphr att glla om produkten ndras utan vrt tillstnd.
Tags
NV-G2E KV-29DR1 Photon X25 DEQ-P9 XV-Z9000 LC-26D44E Vapeur CDM-8900 TTR125-2005 Hitman-contracts Motorola EQ5 SGH-D908 MS7101C Sfera 125 Raychart 435I FAV60700UW Samsung EX1 USR5416 E-105 TW200-2005 80 IS GR-D200us-gr-d200 KDL-V32a12U TX-36PF10 CDX-M8810 DV328AEW XAA KDC-128CR Taboo 2000 K-SC 150 LS-K2464HL HT-DM550 Expert USR5417 Shure SM58 24089 VPC550R EMS2020S CDA-9856 SRA-2400 RX-DT70 P4M800-m7 Recoveryexpert UE-46C7000 RS26ddapn AW2102F Traffic PRO DM-10 Plug-IN XL6600U DV-SV9C Olympus P4V800d-X DV-686A-S MR238 Troubleshoot CDX-GT420U Ultra Zoom PXI-H990 90-QD TIL 641 IP-431 A-SV610PRO DSC-S1900 CMT-MX550I Zoom Q3 240V Laboratory 3 VM70-100 DVR-80PH USR5430 Universalis II Dry Iron Asus P2LB Alarm Boss NEW Picturetel 210 Mini J7 Rodius SEW-eurodrive 108 FA120 WVC200 1650EN Scanmaker I700 - S S-H510V AVF 109 DT50 RSM CMT-Z100IR M 300 Kinetiz 7T Powerpad Plus Dimension C521 Over Riva TT-micro C254 504II EWH-150R Cooker XR-CA400 CD1351S Blade
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101