Texecom Premier 412
|
|
Bookmark Texecom Premier 412 |
About Texecom Premier 412Here you can find all about Texecom Premier 412 like user manual and other informations. For example: .
Texecom Premier 412 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Texecom Premier 412 please write about it to help other people. [ Report abuse or wrong photo | Share your Texecom Premier 412 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Texecom Premier 412, size: 1.2 MB |
Texecom Premier 412
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

INTRUDER ALARM MANUFACTURER
W I N N E R
OF THE YEAR 2000
CONTROL PANEL WITH INTEGRATED COMMUNICATOR
THANK YOU FOR VOTING TEXECOM
The Premier 412 is a 4 zone control panel which can be extended up to 12 zones with the addition of the Premier 8X/Premier 8XE Zone Expanders. This control panel has been designed to provide advanced security for installations where reliable communication of system events is a priority. The circuitry and PCB layouts ensure maximum protection against lightning and other harsh environments. Outstanding features include:
INTEGRATED COMMUNICATOR (PULSE/EXPRESS/FAST FORMAT, CONTACT ID, SIA LEVEL II & PAGER) 4 FULLY PROGRAMMABLE ZONES (EXPANDABLE TO 12) LOCAL & REMOTE UPLOAD/DOWNLOAD VIA WINTEX SOFTWARE & PC 8 FULLY PROGRAMMABLE OUTPUTS (2 SUPERVISED) 2-WIRE/4-WIRE SMOKE DETECTOR COMPATIBILITY 4-WIRE DATA-BUS FOR COMMUNICATING KEYPADS & EXPANDERS 2 TRUE PARTITIONS WITH SEPARATE ENTRY/EXIT, BELL DELAY & DURATION TIMERS ZONE DOUBLING FEATURE 1000 EVENT LOG (TIME & DATE STAMPED) 16 FULLY PROGRAMMABLE ACCESS CODES 4 BYPASS GROUPS CTR21 TELECOMMUNICATION APPROVAL
Ask your distributor today for the new Texecom 28 page full colour Product Guide.
Premier & Wintex are trademarks of Texecom Ltd. (P412.EU2)
F E AT U R E S & E X PA N S I O N
EACH ZONE PROGRAMMABLE TO 1 OF 9 WIRING OPTIONS INCLUDING NORMALLY CLOSED, NORMALLY OPEN, SINGLE EOL, DOUBLE EOL & ZONE DOUBLING EACH ZONE HAS 27 PROGRAMMABLE ZONE ATTRIBUTES PROGRAMMABLE ZONE LOOP RESPONSE TIME ZONE SOAK TEST FACILITY 26 PROGRAMMABLE SYSTEM/PARTITION TIMERS EACH KEYPAD HAS 23 PROGRAMMABLE OPTIONS INCLUDING PARTITION ASSIGNMENT, EMERGENCY ALARM ENABLE/DISABLE, QUICK ARM/DISARM ENABLE/DISABLE & SYSTEM ALARM TONES ENABLE/DISABLE 77 PROGRAMMABLE OUTPUT FUNCTIONS SUPERVISED SIREN OUTPUT - CONFIGURABLE FOR SPEAKER OR BELL DRIVER PRINTER OUTPUT VIA PC-Com STAND-BY BATTERY TEST INSTALLER CODE LOCKING DUAL TELEPHONE NUMBERS FOR ALARM RECEIVING CENTRE DTMF OR PULSE DIALLING FORMATS AUTOMATIC TEST TRANSMISSION PROGRAMMABLE REPORTING CODES FOR EACH SYSTEM EVENT ATTENDED OR UNATTENDED UPLOAD/DOWNLOAD ANSWER PHONE DEFEAT OPTION AUTO BYPASS MODE (PROGRAMMABLE PER PARTITION) PROGRAMMABLE VOLUME CONTROL FOR PANEL/EXPANDER SPEAKER OUTPUT WINTEX UDL SOFTWARE
S P E C I F I C A T I O N
P R E M I E R ELECTRICAL 2 E N D S TAT I O N
Current Consumption Quiescent current <50mA. Alarm current <150mA. Fuses: Mains 230VAC T315mA, 250V, 20mm. Battery 1.6A, 250V, 20mm. Auxiliary 1A, 250V, 20mm. Siren 1A, 250V, 20mm. Data 1A, 250V, 20mm. Zones 4 on board, fully programmable. EOL resistor value 3K3. Panel Outputs O/P 1 and 2 (supervised) switched negative @ 1A. O/P 3 - 8 switched negative @ 100mA. Siren Output (Supervised) Minimum load 4 when used as Speaker driver. Switched negative @ 1A when used as Bell driver. 2-Wire Smoke Detectors ESL429CT and System Sensor 2100TS. Data-Bus 4 wire connection including power. Remote Keypads Up to 6. Digital Communicator: Protocols Pulse/Express/Fast Format (Scancom), Contact ID and SIA Level II. Telephone Numbers 2 up to 24 digits. Dialling Formats Pulse (USA or European) or DTMF. REN 1. Approval CTR21.
POWER SUPPLY
Maximum Total Current Rating 1A with 16.5AC, 25VA transformer. 1.5A with 16.5AC, 40VA transformer. Ripple <5%. Rechargeable Battery Capacity 1.2 to 7Ah.
PREMIER RKP4, RKP16 & RKP16 Plus REMOTE KEYPADS
The Premier RKP4 is the standard remote keypad for the Premier 412 control panel. The Premier RKP16 and RKP16 Plus keypads are used when the system is expanded above 4 zones. Separate indicators for each zone allow the system status to be accessed at a glance Up to 6 keypads can be connected Dual level back-lighting 4-wire connection to data-bus Built-in piezoelectric sounder 2 fully programmable zones (Premier RKP16 Plus only)
ENVIRONMENTAL
Operating Temperature -10C (+14F) to +50C (+122F). Storage Temperature -20C (-4F) to +60C (+140F). Maximum Humidity 95% non-condensing. EMC Environment Residential/Commercial/Light Industrial or Industrial.
PHYSICAL
Dimensions 282mm x 225mm x 80mm.
R E M O T E ELECTRICAL
K E Y P A D S
Operating Voltage 13.7VDC nominal, 9.0VDC minimum. Current Consumption 35mA nominal, 85mA when back lit. Data-Bus 4-wire up to 500m Star, Daisy Chain, or any combination. ENVIRONMENTAL As control panel.
Dimensions RKP4, RKP16 140mm x 105mm x 35mm. RKP16 Plus 145mm x 115mm x 30mm.
PREMIER 8X ZONE EXPANDER ELECTRICAL
Operating Voltage 13.7VDC nominal, 9.0VDC minimum. Current Consumption 35mA nominal, 180mA in alarm with speaker. Data-Bus 4-wire up to 500m Star, Daisy Chain, or any combination. ENVIRONMENTAL As control panel.
P R E M I E R 8 X R E M O T E Z O N E E X PA N D E R
The Premier 8X Remote Zone Expander is wired to the data-bus to provide the following features: 8 fully programmable zones 2 programmable outputs Speaker driver output with programmable volume control
Dimensions 125mm x 65mm x 30mm.
PREMIER 8XE ZONE EXPANDER ELECTRICAL
Operating Voltage 13.7VDC nominal, 9.0VDC minimum. Current Consumption 35mA nominal. ENVIRONMENTAL As control panel.
Dimensions 83mm x 50mm x 12mm.
E U R O P E A N
S T A N D A R D S
P R E M I E R 8 X E LO C A L Z O N E E X PA N D E R
The Premier 8XE Local Zone Expander plugs onto the control panel to provide 8 additional fully programmable zones.
Conforms to European Union (EU) Low Voltage Directive (LVD) 73/23/EEC (amended by 93/68/EEC) and Electro-Magnetic Compatibility (EMC) Directive 89/336/EEC (amended by 92/31/EEC and 93/68/EEC). EN 50131-1 Grades 1 and 2. The CE mark indicates that this product complies with the European requirements for safety, health, environmental and customer protection.
P C- C o m
The PC-Com adds the ability to Upload/Download locally with the Premier 412/816 control panels. One end of the PC-Com simply plugs onto the control panel, whilst the other end plugs into a PC or laptop running the Wintex UDL software.
2000 - 2001 Texecom Ltd.
BEST MANUFACTURER 2000 INTRUDER ALARM MANUFACTURER OF THE YEAR 2000 BEST MANUFACTURER 1999
Cer tificate Number: FM 35285
P 412.EU2

Premier 412 & 816 User Guide (UK)
THANK YOU FOR VOTING TEXECOM
USER GUIDE (UK)
Security Control Panels
Operating Your Alarm System
This document covers the everyday operation of your alarm system, for details on more advanced operation and system programming, please refer to the Premier 412 & 816 Master User Manual.
Away Arming the System
Enter your Access code !!!! followed by the "/# key. The Armed light will flash and the exit sounder will sound for the duration of the exit time.
Part Arming the System
Enter your Access code !!!! followed by the $ key. The system will normally arm immediately, the Armed light will flash slowly indicating that the system is Part armed.
Disarming During Entry
Enter the premises via the designated entry point. The entry tone will sound, proceed directly to the remote keypad and enter your Access code !!!!.
Disarming When Not in Entry
Proceed directly to the remote keypad and enter your Access code !!!! followed by the %/& key. Note: If your system consists of only one partition you will not have to press the %/& key.
Omitting Zones
Enter your Access code !!!! followed by the ' key. Enter the zone or zones to be omitted e.g. 02, 04 etc. When all required zones have been selected, press: "/# to Away arm the system with the selected zones omitted $ to Stay arm the system with the selected zones omitted ( to return to the normal disarmed state with the selected zones omitted
Reset Alarms/Faults
Enter your Access code !!!!, then enter () or press *.
Last Alarm Log
Enter your Access code !!!!, and then enter (+. The remote keypad will display the zones that caused an alarm when the system was last armed. Press ( to return to the normal disarmed state. 2 INS197
Acknowledging a New Service Fault
Should the Service light start flashing, enter your Access code !!!!, and then enter (,. The remote keypad will display all Service Faults (see Service Faults Table on back page). Press ( or *-to acknowledge the fault and return to the normal disarmed state.
Toggle Chime On and Off
Enter your Access code !!!!, and then enter (. or /.
Change User Access Code
Enter your existing Access code !!!!, and then enter (0. Enter your new Access code !!!! followed by the "/# key. Now reenter your new Access code !!!! for confirmation.
Abort Communications
Enter your Access code !!!!, and then enter (1.
Resetting the System Using Anti-code Reset
This feature is normally used in the UK where users are not permitted to reset the panel following a communicated alarm. However, you can reset the panel after entering a unique anti-code remote reset number, which is obtained from your installer or Alarm Receiving Centre. Enter your Access code !!!!, and then enter (2. The remote keypad will display a randomly generated 4-digit code. Make a note of the number displayed and contact the number below: Tel No: ______________________________________ You will be asked to explain the circumstances of the alarm and if the Alarm Receiving Centre or Installer decides that it is not necessary to send an engineer, you will be provided with a 4-digit Anti-code. Enter the anti-code reset number !!!!-at the keypad. If the code is accepted the keypad will sound an acceptance tone and the system will reset and return to the normal disarmed state.
INS197
Service Faults Displayed on LED Keypads Light
3 AC Fail Telephone Line Fault 2-Wire Smoke Alarm Box Tamper & Auxiliary Input: Press. to view type, Lights 1 - 3 will light up: 4 Light 1 = Box Tamper Light 2 = Auxiliary Tamper Light 3 = Auxiliary PA 7 Date or Time Lost Zone Tamper/Trouble Press 3 to view zone number Keypad Tamper/Removed Press 1 to view keypad number Equipment Faults Press 4 to view fault type: Light 1 = Output 1 Fault Light 2 = Output 2 Fault 8 Light 3 = Siren/Bell Fault Light 4 = 2-Wire Smoke Sensor Fault Light 5 = Auxiliary Fuse Failed Light 6 = Battery Fault Light 7 = Service Timer/Zone Soak Test Failed Light 8 = Communication Fault
Fault Condition
Tags
BV9980RDS R580 Js02 LN40C610 9 9D EL-531WG 50PC5D-UL KDL-46XBR2 DFH725 ZP100 CS62DU Integral 3 BH-216 23 EV Lexmark Z13 EMX 660 7020-S TR700SPR KDC-W4537uaug ZVM64X 03R 40 MC CX-2600 BN315 55-3202-7 TOP Cry-instincts FAX-B820 Plantronics T10 ME-25 SLV-D990PR DVB216 SGH-T719 TS-A6962R LG MG23 BSZ 18 703SH LS6200 Coder 1 Rcs-lx60d Yamaha RY20 CQ-C1110U SBM10 AM1250 AK-2464 PRS-505-SC Finder CQ-VD7001N WFE0666A GR-DVL510u-gr-dvl510 PMP518M SMH7187STG Printer 720 DCS460-18 Watches Accessories LP120HED-y8 WF-7776TTC DVP-NS718H M-5130SH CDX-L350 RS275acwp XAA Lp201 Timex W-11 BT3100 Hamilton 10HF Twinmate ZRB323WO1 CH-453 CDX-GT54UIW TY-42TM6B 3-device Finepix A360 SA-GX100L 27LB220B4U 46D653E TX-32LX85P Battle Bugs DCR-DVD408E P-touch 1010 610 S SL-Q210 CQ-C7300N IBM 6787 KRF-V7050D 310 315 T240HD Whistler 1530 CE200 DVD-SH895 XEC PL150 PSR-110 UR3-EXP 2243LNX RC5215P Fr KD-D4 FB 630P 859 MT KEH-8400R IP011 Premier 412 42PF9966-37B
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101







