Reviews & Opinions
Independent and trusted. Read before buy Fleck 5600SE!

Fleck 5600SE


Bookmark
Fleck 5600SE

Bookmark and Share

 

About Fleck 5600SE
Here you can find all about Fleck 5600SE like water softener and other informations. For example: parts, manual.

Fleck 5600SE manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Fleck 5600SE please write about it to help other people.
[ Report abuse or wrong photo | Share your Fleck 5600SE photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Fleck 5600SE, size: 1.2 MB

 

Fleck 5600SE

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 1. Page 1 of 1.
Anonymous 4:06pm on Saturday, October 16th, 2010
pretty good

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

MODEL 5600SE Downflow - V2.0
Master Programming Mode Flow Chart
With Time of Day Display set to 12:01 P.M., Push and hold both the Set Up and Set Down Buttons for 5 seconds. US/Metric Display Format Example: US Display Format [U--1]
Regeneration Type Example: Metered Delayed Regeneration [7--3]
Treated Water Capacity Example: 1,000 Gallons [1000]
Regeneration Time Example: Regenerate as needed at 2:00 A.M. [2:00]
Note: 1. 2. 3. Set Time of Day Display to 12:01 P.M. Push and hold both the Set Up and Down Buttons for 5 Seconds. Push Extra Cycle Button once per display until all displays are viewed and normal operation is resumed. Option setting displays may be changed as required by pushing either the Set Up or Down Button. Depending on current valve programming certain displays will not be able to be viewed or set.
Regeneration Day Override Example: Regenerate at a minimum frequency of 3 days [A--3]
Regeneration Cycle Step #1 Example: 10 minute step time [1-10]
Regeneration Cycle Step #2 Example: 60 minute step time [2-60]
Regeneration Cycle Step #3 Example: 10 minute step time [3-10]
Regeneration Cycle Step #4 Example: 12 minute step time [4-12]
Regeneration Cycle Step #5 Example: Step 5 Cancelled [5OFF]
Flow Meter Size Example: 5600SE 3/4 Turbine Flow Meter [F133]
Valve Type Example: 5600SE Valve [o--1]
Line Frequency Example: 60Hz Line Frequency [LF60]
Master Programming Mode is exited. Normal Operation is resumed.

Page 1

Printed in U.S.A.

Master Programming Mode

Service Flow P.M.

Program Indicator

Program
Set Up Button Set Down Button

Extra Cycle Button

Regeneration Display
Step 1 - Brine/Rinse Step 2 - Backwash Step 3 - Rapid Rinse Step 4 - Brine Refill
Entering Master Programming Mode
With Time of Day Display set to 1201 PM, push and hold for 5 seconds both the Set Up and Down Buttons. The Program Indicator will turn on to signal that this mode is entered. In this mode all possible option settings may be viewed. 1. US/Metric Display Format (U) Depress the Extra Cycle Button. This display is used to set the desired display format. This option setting is identified by the letter U in the first digit. There are two possible settings:
US Format uses gallons for volume with a 12 hour timekeeping format. Regeneration timing in minutes.

Example -

Metric Format uses liters for volume with a 24 hour timekeeping format. Regeneration timing in tenths of minutes.
Cubic Meter Format uses m3 for volume with a 24 hour timekeeping format. Regeneration timing in tenths of minutes.
The Set UP and DOWN Buttons will adjust this value. 2. Regeneration Type (7) Depress the Extra Cycle Button. This display is used to set the Regeneration Type. This option setting is identified by the number 7 in the first digit. There are 3 possible settings:
Timeclock Delayed. The control will determine that regeneration is required when the set Regeneration Time has been reached. The Regeneration Day Override setting will determine which days a regeneration cycle will be initiated.
Meter Immediate. The control will determine that regeneration is required when the available volume of softened water drops to or below zero. Regeneration to begin immediately.

Page 2

Master Programming Mode (Contd.)
2. Regeneration Type (7) (Contd.)
Meter Delayed. The control will determine that a regeneration is required when the available volume of softened water drops to or below zero. Regeneration is to begin immediately at the set Regeneration Time.
The Set UP and DOWN Buttons will adjust this value. 3. Treated Water Capacity (No Display Code) Depress the Extra Cycle Button. This display is used to set the amount of treated water (gallons/liters) that can be produced by the unit before a regeneration cycle is required. With Meter Delayed Regeneration Type set, it will be up to the programmer to determine a reserve capacity and subtract that value from the calculated full capacity of the unit. This display will not be viewed with Timeclock Regeneration Type set. Example: Regenerate every 700 gallons, liters, or m3 The Set UP and DOWN Buttons will adjust this value. 4. Regeneration Time (No display Code) Depress the Extra Cycle Button. The next display viewed is the option setting for Regeneration Time. It is identified by a non-flashing colon between two sets of numbers. Set the desired time of day that a regeneration may occur, if required. This display will not be viewed with Meter Immediate Regeneration Type set. Example: 2 oclock A.M. regeneration time -

(A.M. Indicator Dot On)

The Set UP and DOWN Buttons will adjust this value. 5. Regeneration Day Override (A) Depress the Extra Cycle Button. This display is used to set the maximum amount of time (in days) the unit can be in service without a regeneration. This option setting is identified by the letter A in the first digit. With Meter Immediate Regeneration Type selected, regeneration will begin at the same point in time some amount of days ago when the last regeneration cycle was initiated. With Timeclock or Meter Delayed Regeneration Types selected, regeneration begins at the set Regeneration Time. An OFF setting will cancel this feature with all regeneration types except Timeclock Regeneration were it must be used. Examples: Override every 7 days -

[ Cancel setting - [

] ] (Meter Immediate or Delayed Regeneration Types Only)
The Set UP and DOWN Buttons will adjust this value. 6. Regeneration Cycle Step Programming (1) (2) (3) (4) (5) (6) Depress the Extra Cycle Button. The next 2-4 displays viewed are part of a series of option settings used to program the Regeneration Cycle. Up to 4 steps can be programmed. Each display is used to set the duration time in minutes (or tenths of minutes - Metric) of that specific step in a regeneration cycle. A step # will turn on for the regeneration cycle step being programmed. Regeneration steps are skipped by setting the display to 0 and regeneration ended by setting the step # after the last active step to OFF, as shown below and on the next page: Examples: Regeneration Cycle Step #1 - 8 minutes Regeneration Cycle Step #3 - skipped -

Page 3

6. Regeneration Cycle Step Programming (1) (2) (3) (4) (5) (6) (Contd.) Examples: Regeneration Cycle Step #4 - cancelled -
Regeneration Cycle Step #4 - 8.5 minutes -

(Metric Format)

Depress the Extra Cycle Button once per display to advance through Regeneration Cycle Step Programming. The 5600SE control has a separate brine tank fill cycle. Your desired salt setting must be calculated, using the blue (.25 gpm) or black (.5 gpm) rate of refill (in gpm) times your timer setting. Then using one gallon of fresh water dissolving approximately 3 lbs. of salt, calculate your refill time. Example: lbs. salt 3 B.L.F.C. Size = refill time in minutes, 10 lbs. salt 3 .25 = 13.3 minute refill The Set UP and DOWN Buttons will adjust these values. 7. Flow Meter Size (F) Depress the Extra Cycle Button. The next display is used to set the flowmeter size. This option setting is identified by the letter F in the first digit. In this display set the proper amount of pulses generated by the flow meter for each gallon or liter of water flow. This setting will not be viewed with Timeclock Regeneration Type selected. Examples -

3/4 Turbine Flow Meter (US Format) 3/4 Turbine Flow Meter (Metric Format)
The Set UP and DOWN Buttons will adjust this value. 8. Valve Type (o) Depress the Extra Cycle Button. This display is used to set the type of valve used with the control. This option setting is identified by the letter o in the first digit. There are two possible selections with #1 being the required setting: Examples -
5600SE Valve Operation. Option Not Typically Used.
The Set UP and DOWN Buttons will adjust this value. 9. Line Frequency (LF) Depress the Extra Cycle Button. This display is used to set the frequency of the power applied to the control. When properly set, all timekeeping functions will remain accurate. This option setting is identified by the letter o in the first digit. There are two possible selections. Examples -
50Hz Line Frequency Operation. 60Hz Line Frequency Operation.
The Set UP and DOWN Buttons will adjust this value.
Exiting This Option Setting Level
Push the Extra Cycle Button once per display until all have been viewed. The Program Mode will be exited and normal operation resumed.
Resetting Permanent Programming Memory Push and hold the Set Up and Down Buttons for 25 seconds or until the Time Of Day Display resets to 12:00 P All.M. option settings will then reset to default values. Control programming will then have to be reset as necessary.

Page 4

 

Tags

SA5285BT KX-TG2357 NV-DS35EG RFX-2200 Strd2090 Way FAX DMC-TZ11 Doro 630R Machine Extensa-4420 HDR-TG5E BSG71360UC Manual NVX-DV609 4000 Plus BGW 500D Dvcr-A500 M1921A-BT Firewall 6 Parts YZF-R6RC S-civilization III Alesis IO2 PC POD BE 710 KIP 3000 Photosnap 9 LE46S86BD MZ-R700 WT-R807 Xvs650L PV-GS90P CLP-315W F40-1992 Sportback ZFU228WO EF2280 VPC-C6EX MAM 2100 KX-FLB813EX X5 2003 SGH-T739 Maker Aspire-1650 BMW 740D RX-V3900 Samsung I688 HVL-F36AM DR-MH200SE PC E800 LSP-340 Motor 100 Beveled Face Photophone K-521 AG-7350 ML-1640 ETS Nokia 6102 Temporis 12 Printer RD2010 Sagem D80V RSX-1056 9HP-2002 Afti 40 6350 Live SH-D162D 22PFL3403 10 Sirius ST2 CE340NFX 503CW GCA-510 KH 6519 DGB-500 VA905 RF266aewp KDC-5070R AC-SQ950D Lifebook C HX6932 Stylus C88 Extensa 5420 KDL-26T3000 Rosieres 1401 SG-71 Blend KEH-M4500 Cordless 7 5920F MF-HE700 Building SET Casio 4733 PRO-E Serie 3000 N DSC-T100 B CDX-C450X R 145 740GM-p21 22863 Silence Vitality

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 